Configuring Work Center Status Parameters

Use the Work Center Status Parameters form to configure efficiency levels and refresh intervals for work centers. If you do not configure efficiency levels and refresh intervals for a work center, the generic values on the Transaction Set Maintenance form will be used for that work center. For more information about efficiency levels and refresh intervals, see Work Center Efficiency Overview.

  1. Open the Work Center Status Parameters form.
  2. Create a new parameter set for a work center or select an existing parameter set to modify:
    1. To create a new parameters set, click New.
    2. To modify an existing parameter set, select a work center from the grid.
  3. Specify or review this information:
    Work Center
    If you are creating a new parameter set, select a work center. All work centers in your ERP system are available in the drop-down menu. If you are modifying an existing parameter set, the work center name and description are displayed.
    Refresh Interval
    Specify how often the efficiency percentage should be calculated.
    High Efficiency Level
    Specify the minimum efficiency level that must be reached for a work center to be operating at high efficiency.
    Medium Efficiency Level
    Specify the minimum efficiency level that must be reached for a work center to be operating at medium efficiency. Work centers that have efficiency percentages below this value are operating at low efficiency.
  4. Click Save.
Related topics