MetaRF.ini

The metarf.ini file is the main configuration file used to change the behavior of Meta RF.

Parameter Name

Description

HH_locale

Determines the language when the login screen is displayed. Setup this parameter as a variable in pragma or in the .profile.

HH_device

Device Type – 8x40 or 16x20. Setup this parameter as a variable in pragma or in the .profile if multiple devices are used.

HH_SERVERLIST

A list of secondary servers or ports for high availability.

HH_PORT1/2/3

The servers and ports are cycled through looking for a valid connection to the socket server. Typical default install values: 10023, 6874, 6875 (respectively).

HH_ALLOW_DECIMAL_VALUES_IN_QTY

Determines if the Qty fields accept decimals Possible values: YES, NO

HH_ABOUTKEY

The function key used to launch the HH_ABOUTSCREEN. Typically, not changed, default value is F1

HH_ABOUTSCREEN

The name of the RF screen (ABOUT) that displays when the HH_ABOUTKEY is pressed. Typically, not changed, default value is ABOUT

HH_MAXFIELDSIZE

The maximum allowable size of an editable field value when a MASK size is not applicable. Typically, not changed, default value is 250.

HH_NUMSCREENS

Part of the RF screen layout geometry that is used. Set to 1 for 16x20 ‘hand-held’ devices, and 2 for 8x40 ‘truck-mounted’ devices. Possible values are 1 or 2.

HH_MBYTESCROLL

Whether or not error messages are scrolled on one long line or span multiple screen lines.

HH_dospassword

The password that must be entered to close the Meta RF application at the Exit menu.

HH_CR_IS_LF

1 = a CR (ASCII-13) is changed to a LF (ASCII-10) during barcode input.

0 = a CR (ASCII-13) will remain (ASCII-13)