New feature

This section describes the new features that are available in this production update.

New versioning standard

Infor WMS has adopted the new Infor standard version number format. The full version of an update has three segments:
  • YYYY. = the year where the release will first deploy to production, followed by a dot
  • MM. = the month where the release will first deploy to production, followed by a dot
  • NN = the sequence number of the supplementary update to the YYYY.MM version

In preparation for the October update, the version number is 2021.10.00. Depending upon the number of supplementary updates that occur before the October update is deployed, the third segment of this number might change, for example, 2021.10.NN.

The versioning standard for documentation will be 2021.x.

This new versioning standard replaces the previous version number format for Infor WMS, which was 2021.MM.

New RF lot attribute validation

On the RF Lot Attribute Validation page, you can determine which lot attributes are visible or captured during RF transactions at the facility level. If you select the Required check box for a lottable, then the Visible check box is automatically selected and cannot be cleared. When the Visible check box is selected for a lottable, the lot attribute is displayed on the RF screen. When the Required check box is selected for a lottable, then you must specify those lot attributes on the RF screen.

These RF screens have been modified to allow the display and validation of the lot attributes:
  • RF Directed Putaway Task
  • RF Directed Replenishment Task
  • Directed Cherry Pick Replenishment & Multi Cherry Pick Task
  • RF Directed Move Task
  • RF Directed Cycle Count Task - Including Supervisor Counts
  • Cluster Picking (all options)
  • RF Directed Assignment Picking - Including user entered Assignment Picking
  • RF Directed Pick Task - Includes by Order and by Wave

The RF Lot Attribute Validation field has been added to the Outbound tab on the Item page. Select STD to assign RF validation to the item.

New Fkey options for RF Outbound QC process

When using RF devices to add accepted and rejected quantities to the outbound QC inspections, you can now delete or reset inspection quantities from the RF screens. The F3 option on the DC01 screen can be used to delete all QC data for the container. The F3 option on the DC02 screen can be used to reset all QC data for a specific item within the container. The F4 option on the DC02 screen can be used to close the container.

You can use the new AutoCloseQCContainer system setting to prevent the container from automatically being closed when all details have been fully inspected. If AutoCloseQCContainer is set to ON or if the setting does not exist in the table, then the container closes automatically. If set to OFF, then the container close process is not performed. The default is ON.