Adding validations
        
         
          - Open the settings.conf file with a text editor. The file is located in the \conf subdirectory of the WBCS installation file. 
- Locate the existing validation settings, if any. 
- Specify a new setting for each validation you want to add in the form: class.validation.ClockType.### = com.infor.wfm.clock.server.validation.ValidationTypereplacing the following:
            
             - ClockTypewith the clock type to which the server applies the validation, you want the server to apply the validation. For example, specify- SYNELto configure the WBCS to apply the specified validation to the Synel clock.
- ###with a unique number for the set of validations applied to the clock type, incremented by one for each validation setting you add for the clock type. For example, if you there are three validation settings for the Synel clock, they should be numbered- 001,- 002, and- 003. When you add a fourth setting, replace- ###with- 004.
- ValidationTypewith the specific validation name you want to add. Type one of these options:- 
               - AreaValidation
- BadgeValidation
- BreakLengthValidation
- ConsecutiveTypesValidation
- DepartmentValidation
- DepartmentAreaValidation
- DocketValidation
- DocketAreaValidation
- IgnoreSwipeValidation
- JobValidation
- JobAreaValidation
- PINValidation
- ProjectValidation
- ProjectAreaValidation
- SameMinuteValidation
- SaveUnprocessedSwipeValidation
- ScheduleValidation
- StatusValidation
- SupervisorValidation
- SupervisorEmployeeValidation
- SupervisorReaderValidation
- TerminalIPValidation
- TimeCodeValidation
- TimeCodeAreaValidation
 
 
 
- Save the file and exit the text editor.