Adding validations
- Open the settings.conf file with a text editor. The file is located in the \conf subdirectory of the WBCS installation file.
- Locate the existing validation settings, if any.
- Specify a new setting for each validation you want to add in the form:
class.validation.ClockType.### = com.infor.wfm.clock.server.validation.ValidationType
replacing the following:
ClockType
with the clock type to which the server applies the validation, you want the server to apply the validation. For example, specify SYNEL
to configure the WBCS to apply the specified validation to the Synel clock.
###
with a unique number for the set of validations applied to the clock type, incremented by one for each validation setting you add for the clock type. For example, if you there are three validation settings for the Synel clock, they should be numbered 001
, 002
, and 003
. When you add a fourth setting, replace ###
with 004
.
ValidationType
with the specific validation name you want to add. Type one of these options:
AreaValidation
BadgeValidation
BreakLengthValidation
ConsecutiveTypesValidation
DepartmentValidation
DepartmentAreaValidation
DocketValidation
DocketAreaValidation
IgnoreSwipeValidation
JobValidation
JobAreaValidation
PINValidation
ProjectValidation
ProjectAreaValidation
SameMinuteValidation
SaveUnprocessedSwipeValidation
ScheduleValidation
StatusValidation
SupervisorValidation
SupervisorEmployeeValidation
SupervisorReaderValidation
TerminalIPValidation
TimeCodeValidation
TimeCodeAreaValidation
- Save the file and exit the text editor.