Time synchronization settings
| Setting | Description | 
|---|---|
| technician.cmi.sendtimeinterval = 3600 | The frequency (in seconds) the set timecommand is sent to the CMI clock. | 
| technician.cmi.sendtimeallowance = 60 | The time interval between polls to the CMI clock. If the time interval between 2 sequential CMI polls exceed this allowance, the time is updated on the clock. | 
| server.clock.time.difference = 5 | The maximum time difference in seconds, between the WBCS and the clock. If the time difference is more than this value, the WBCS resets the clock's time. |