FORCE_CLOCK_ON_DAY = false

If the value of the FORCE_CLOCK_ON_DAY registry parameter is false, then directionless clock processing first checks for any schedules on the previous day, the current day, or the next day. The clock is assigned to whichever scheduled day is within the number of minutes specified by the DIRLESS_PROXIMITY registry parameter.

If a clock is within the DIRLESS_PROXIMITY of more than one scheduled day, it is assigned to the day with the closest proximity.

If no schedules are found on the previous, current, or next day, the clock is assigned to the same day as the clock date.