Virtual clock settings
Virtual Clock specific settings in WBCS.
Setting | Description |
---|---|
reader.VCLOCK.port = 4001
|
Specifies the port the WBCS uses to listen to virtual clock
connection requests. The default port is
4001 .
|
reader.VCLOCK.interval = 1
|
Indicates how often, in milliseconds, the WBCS will check
the virtual clock heartbeat. The default value is
1 .
|
reader.VCLOCK.heartbeat = 20000
|
This parameter defines the live time, in milliseconds, of a Synel standalone clock. Live time is defined as the amount of time the clock will remain active in the absence of a send request to the clock server. If the clock does not send a request to the clock server within the specified time, the clock is designated as not connected. The live time is set to three times the value provided in this parameter. This value should be consistent with the interval in the virtual.conf file in your virtual clock installation directory. The default value is 20000 milliseconds. |
reader.VCLOCK.dnsEnabled = false
|
This parameter, if set to true, allows the WBCS to search for a clock by the Windows name instead of an IP address. The default value is false. For more information on name resolution, see Name resolution in WBCS. |