Adding readers

To add a reader:

  1. Select Maintenance > Reader Setup > Readers.
  2. Click Create New Entry.
  3. Specify this information:

    Reader configuration varies with reader type. The fields on this screen must be set up in accordance with the Export Task field mappings. See Interfaces.

    Reader
    Specify the name of the new reader.
    Description
    Specify a description of the new reader.
    Reader Type
    Select the clock type: WB8000, WB9000, TimeTrack.
    Note: The swipe sharing feature is only supported for WB8000 and WB9000 clocks.
    Reader Group
    Select the reader group to which the reader is assigned from the lookup.
    IP Address
    For clocks connecting to the standalone clock server, specify the IP address of the reader. For WB8000 and WB9000 clocks, specify a dummy IP address of 1.1.1.1 initially. After the clock connects to the application, the dummy IP address is overwritten with the actual IP address that is provided by the clock.
    Reader Status
    Indicate whether the reader is online or offline from the lookup. This does not apply to the WB8000 and WB9000 clocks.
    Reader Zone
    Readers can be associated with various locations or zones within an organization. Typically, all readers belong to the same zone.
    Controller
    Specify the IP address of the DR600 reader. This field can also be used with other reader models. This field is used when multiple readers are linked in a chain.
    Password
    Optionally, specify a password for the reader and reader server.
    Last Poll Date
    This is a read-only field that displays the last date and time the reader communicated with the clock server. For the WB8000 and WB9000 clocks, this field displays the last date and time the reader communicated with the application.
    Message
    Specify a message to be displayed on the clock reader.
    Time zone
    Select the time zone of the reader from the lookup.
    Sub Address

    (Applies to CMI readers only) Similar to Controller, this field lists the order that readers are linked in a chain (1,2,3).

    Download File

    (Applies to CMI and RSI readers) Specify the location of the reader’s download file. The download file is the program that defines the reader’s behavior.

    Auto Connect

    (Applies to CMI and RSI readers) Select the check box to define when the reader connection to the server takes place.

    Display Size
    (Applies to CMI readers only) Specify the size of the CMI reader’s display, such as 2x20 or 4x20.
    Disable PIN Validation
    Select the check box to disable employee PIN validation so that employees only need to provide a badge, but not a PIN.
    Biometric Mode
    • None: Select this option to disable biometric validation. This is the default setting.
    • Identification: Select this option to allow employees to clock by only providing a fingerprint for either the 8000 Series or 9000 Series clocks. Employees have to enroll a fingerprint on the clock and then use the fingerprint to validate themselves. A badge is not required for clocking with this option, although for configuration purposes a placeholder badge for the employee must be entered in the system.
    • Verification: Select this option to enable biometric validation for either the 8000 Series or 9000 Series clock so that employees have to enroll a fingerprint on the clock and then use the fingerprint to validate themselves after providing a badge.

    For more information on enabling biometrics in the 8000 Series or 9000 Series clocks, see the Infor system administration guide for your clock.

    Enable Schedule Validation
    Select the check box to verify that the employee is scheduled to work at the time of the clock punch. If an employee attempts to punch in when they are not scheduled, the punch is rejected.
    Enable Swipe Sharing
    Select the check box to enable swipe sharing for a WB8000 or WB9000 clock. Swipe sharing allows an employee to use other clocks in their workplace that also have swipe sharing enabled. Employee swipes are shared between all clocks that belong to a single reader group.

    To disable swipe sharing for this reader only, clear the check box. This change has no impact on the swipe sharing status of the reader group.

    Note: You cannot enable swipe sharing for the reader if swipe sharing is not enabled for the reader group that the reader belongs to. For more information on how to enable swipe sharing for a reader group, see Adding reader groups.

    For more information on configuration and the limitations of this feature, see the system administration guide for your clock.

    Start Grace
    Specify the grace period at the start of the employee’s shift during which an employee's swipe is considered valid. For example, if there is a 15 minute grace period set and an employees swipes in 10 minutes after the shift has started, the employee is considered to have swiped in on time.
    End Grace
    Specify the grace period at the end of the employee’s shift during which an employee's swipe is considered valid. For example, if there is a 15 minute grace period set and an employee swipes off 10 minutes before the shift has ended, the employee is considered to have swiped off on time.
    Swipe Method
    Select the swipe type that is used by the clock:
    • Default
    • Swipe and Go:

      PIN or biometric validation is not configured for this swipe type and employees only provide a badge during a clock in or out. The clock registers the swipe as type 11, which the clock-processing task processes as an IN or OUT based on the previous swipe.

    • Directionless: PIN or Biometric validation can be configured for a directionless swipe. This method requires that the employee swipes a badge, provides a PIN or biometric validation if necessary, and then selects the IN or OUT button on the clock. Regardless of which button is selected, the swipe is recorded as type 11, which the clock-processing task processes as an IN or OUT based on the previous swipe.
  4. Click Save.