Configuring the Clock for Viewing Swipes

To enable this feature, use the configuration update feature to configure these parameters on the clock(s) where the feature is required. For more information on configuration updates, see Configuration Updates for the Clock.

To configure the clock for viewing swipes:

  1. Specify how long in days the clock will retain swipe information before purging the data:

    db.journal.purge.interval = 30

  2. Specify the maximum number of swipes an employee can view:

    view_last_swipes.maxCount = 20

  3. Specify the maximum number of days of swipe information an employee can view:

    view_last_swipes.maxDays = 5

  4. Specify the types of swipes an employee can view, for example clock in, clock out, job changes, and department changes:

    view_last_swipes.types = 01, 02, 03, 04, 06, 07, 08, 11

  5. Configure a menu item or function key based on how employees will access the feature. Out-of-the-box configuration provides access to the feature from the clock menu as well as a function key.