To add a custom process

A custom process groups together custom activity parameters and/or tests in stages and defines specific settings and/or expected results for each parameter or test.

  1. Select SIM Configuration in the Surgical Instrument Management menu.
  2. Select Custom Processes > Add in the Configuration page.
  3. Select an activity for the custom process.
  4. Specify the name/description of the custom process.
    Note: 

    Do not use duplicate custom process description entries to avoid confusion when creating custom process loads.

  5. Select to Require Cycle Number on load. Applicable for handheld.
  6. Select a stage and click Add to add a stage to the custom process.
  7. Click on Add Parameter/Test to add parameters or tests for the stage added in previous step.
  8. Specify this information.
    Expected Result

    Select to display the planned conclusion of the sterilization process.

    Display at Load Setup

    Select the display field to use for the process.

    Comment

    Specify supplementary information for the process.

  9. Click Save.