Adding a digital OPC item
- Select . The OPC Items screen is displayed.
- Click Add. The Add window is displayed.
- Specify this information on the OPC Item tab:
-
OPC Item Type
-
The type of OPC item must be set to Digital.
-
Tag Name
-
The name of the OPC item.
-
Address
-
The tag’s address in the OPC server.
-
Description
-
The description of the OPC item.
-
OPC Server
-
The OPC server used for reading and writing tags in the from and to fields.
-
OPC Group
-
The OPC group to which the tag is assigned.
-
Machine
-
The machine associated with the OPC item
-
Action
-
The action to perform when the OPC item value changes. This field can be blank if an action, other than the standard OPC item type action, is not required.
-
Formula
-
An expression that defines how to calculate the OPC item value based on other OPC items. This field is optional and can be blank if necessary.
-
Digital Type
-
The OPC digital type to collect. Possible values:
- Machine Event: A machine event linked to a machine event type is recorded.
- Process Parameter: A Binary or Boolean value (for example: 0, 1, true, or false) is recorded.
-
Event Type
-
The specific machine-event type to generate. This field is enabled only if the Digital Type field is set to Machine Event.
-
Type
-
The type of transition required to record a machine event. This field is enabled only if the Digital Type field is set to Machine Event. Possible values:
- On data change: A machine event is recorded when the OPC item value changes.
- On data condition match: A machine event is recorded when the OPC item value changes to a defined value.
-
OPC Alarm?
-
If this check box is selected, an alarm is triggered when the machine event is recorded.
- Click OK.