Variables tab
You can specify this information:
- Variable Step Plan
-
The order in which variables, heads, samples, and positions are stepped through during inspection. The format to be specified as
H(1:*);S(1:*);V(1:*);P(1:*). See, Variable step plan. - Hide Variable data entry form
- If this check box is selected, the application hides the variable entry form. You must specify all data through the spreadsheet.
- Variable Spreadsheet Layout
-
The manner in which the variable data is displayed on the data entry page. Possible values:
- S as row title, V, H & P as columns (SxVHP)
- P as row title, V, H & S as columns (PxVHS)
- H & S as row titles, V & P as columns (HSxVP)
- H, S & P as row titles, V as column (HSPxV)
- H as row title, V, S & P as columns (HxVSP)
- V, H, S & P as row titles, Value in column (VHSP)
- V as row title, H, S & P as columns (VxHSP)
- Display Plan
-
The sequence in which the measurements are displayed on the data entry screen. The format to be specified as
H(1:*);S(1:*);V(1:*);P(1:*). See, Variable display plan. - Enforced Data Entry Policy
-
Determines when operators can save a quality check that includes variable data. Possible values:
- No Policy - Save any time: The operator can save the quality check any time.
- Enforce at least 1 measurement: The operator must record at least one measurement to save the quality check.
- Save disabled until all measurements entered: The operator must record all measurements to save the quality check.
- Allow Remeasurement
-
Determines when an operator can remeasure data during inspection. Possible values:
- Always: The operator can remeasure data.
- Never: The operator cannot remeasure data.
- Only for UDI Steps: The operator can only remeasure data through a gauge device.
- Only for Keyboard Steps: The operator can only remeasure data using a keyboard.
- OOS Primary Warning Mode
-
Determines how the application displays out-of-specification warnings when operators enter data manually. Possible values:
- Disable: There are no violation alerts.
- Warn: Warnings are displayed for primary entries.
- Alert: Alerts are displayed, which must be acknowledged for primary entries.
- OOS Secondary Warning Mode
-
Determines how the application displays out-of-specification warnings for data entered automatically or calculated using a formula. Possible values:
- Disable: There are no violation alerts.
- Warn: Warnings are displayed for secondary entries.
- Allow Ad-Hoc Device Switching
- If this check box is selected, the application enables the operator to switch device entry cells to keyboard mode at any point during the inspection.
- Raise Device Switch Alarms
- If this check box is selected, the application raises an alarm when device entry cells are switched to keyboard mode manually or automatically.