Example of maintenance procedure step
These are examples of configuring a maintenance procedure step for measuring a blade.
Example 1:
- Step Order: 1
- Step Type: Pass/Fail Check
- Instructions: Check if the blade is bent.
Example 2:
- Step Order: 2
- Step Type: Variable
- Instructions: Measure the BESS (sharpness) of the blade before sharpening.
- LSL:
- Nominal:
- USL:
- Units: BESS
Example 3:
- Step Order: 3
- Step Type: Variable
- Instructions: First sharpen the blade and then remeasure the BESS.
- LSL: 45
- Nominal: 50
- USL: 60
- Units: BESS