Restarting EC Application

When Grid is started, EC Application is started. When EC Application is started, grid fulfils the initial conditions in the binding settings. The binding settings are the number of initial, minimum, and maximum nodes in EC. The first node to start will use the grid property status, this status is used grid-wide.

If you modify the grid property settings, you must restart (stop and start) all EC Server nodes for changes to take effect. After a restart, all EC server nodes will have the same application property status.

If you modify the EC Application properties, you must restart EC Application for changes to take effect. Before you can restart EC Application, you must restart Grid.

Use these guidelines to restart EC Application

  • Invoke Start only if you Stopped the application.

  • When EC Application is started, do not select to immediately shutdown the nodes.

  • Depending on the complexity of your EC configuration, you must always properly stop EC application.

    Other EC application configuration do not require a stop action. During shutdown, a node warming message may be displayed, you can proceed with the shutdown.

Use this procedure to restart EC Application:

  1. Log on to LifeCycle Manager as administrator.
  2. In the LCM Applications tab, select the grid node where EC application is installed.
  3. Right-click IEC Application <version> > Grid <version> > Application Stop Application.
  4. Right-click IEC Application <version> > Grid <version> > Application Start Application.

    The view shows an icon to indicate the status of an application.

    • A green arrow icon means start.

    • A red square icon means stop.