Configuring settings for LoadAdvanceShipNotice

Follow these steps to receive and process M3_AdvanceShipNotice_Load_In.

  1. In 'M3 Stock Msg Partner.Open' (MMS865), create a message partner and specify this information:
    Whs
    Leave blank.
    Msg
    Specify I.
    Partner
    Specify the name of the system that sends the LoadAdvanceShipNotice. Currently, only SW is valid.
    Msg type
    Specify BOD.
  2. Select Options > Create.
  3. In (MMS865/E), specify a valid M3 user in the parameter 300 Partner manager and verify these values:
    Msg direction
    Specify I-Input.
    Partner
    Specify SW.
    Msg type
    Specify BOD.
  4. Select Administration Tools > Enterprise Collaborator Administration. On the Server tab, select Agreement Control Properties and locate M3_AdvanceShipNotice_Load_In.
  5. Ensure that the M3beWarehouseInterfaceProcessFlag control property has one of these values:
    Value Description
    *AUT AdvanceShipNotice is created in an asynchronous mode using a batch job.

    This setting is recommended for high volume environments. Users can find, correct, and re-run failed messages in (MHS850). They can also use the mailbox functionality in Infor Infor M3 Business Engine to be notified when a message fails.

    Note: Error messages are not returned by the API.
    *EXE MHS850MI is run and the AdvanceShipNotice is created in M3.
    Note: Control properties enable messages to be processed online or through batch jobs in Infor Infor M3 Business Engine. Leaving the control properties value blank means that the user must manually run the messages through the 21 option in (MHS850).
  6. Click Save.
    Proceed as follow to fulfill the prerequisite for the Address ID.
  7. In Infor M3 Business Engine, open 'Supplier. Connect Address' (CRS622).
  8. Browse through the Supplier field and select the data that is used in the transaction.
  9. In 'Supplier. Connect Address' (CRS622), specify this information:
    Address type
    03
    Address number
    PICKUP
    Valid from date
    Select a date.
  10. Click Create.
  11. Input all mandatory fields on (CRS622/E).
  12. Press Enter.