Enable resending files through MNS950 for IDM output

This development enables the automatic resending of output when using an Infor Document Management (IDM) service ID (communication type 3 and 6).

- MNS950 output resend auto job must be running. MNS950 only resends the jobs in 'Output. Manager per Job' (MNS270) where the status is MSG and the error message is related to an IDM connection failure. That is, message ID is 'S_02012'. It does not resend the jobs in (MNS270) where the status is MSG but the error message is not related to an IDM connection failure. That is, message ID is not 'S_02012'. Also, it does not resend jobs in (MNS270) where the status is FAI. The same applies with the Streamserve's automatic resend, only jobs created in the last 24 hours are resent.

- For grouped output, when manually resending records in 'Output. Manager per Group Content' (MNS271), the (MNS270) status stays at MSG until all records in (MNS271) have been resent successfully. This means when MNS950 runs, it stills resend the (MNS271) records that have been manually resent.

- For grouped and ungrouped outputs mixed in the same (MNS270) job, manually resending an ungrouped output first changes the message ID to 'S_01853' so when MNS950 runs, it is not able to resend it.

2221698