Verifying the configuration

Verify that the connections are set up correctly by performing these steps:

  1. Use the information in Country configurations to understand which BODs are supported in the LSP function, and which order they need to be published in, if applicable.
  2. Publish the BODs according to your ERP's Integration Guide.
    Note: Your ERP may only support a subset of the BODs listed under the relevant LSP function.
  3. Use OneView to view the progress of the BODs through ION to LSP.
  4. To verify that ION is receiving BODs from LSP, monitor these areas in Infor ION Desk:
    • Select Connect > Manage > Active Connection Points to show the message queue counts.
    • Select Connect > Manage > Message Trace to show individual messages, if they are enabled.
  5. After you create and activate document flows to other products, you can check the message inbox area of the other products, to ensure that data is flowing between the systems.
    Note: If you are unable to see the BOD data within LSP, refer to the section on Troubleshooting for hints and tips.