qmptc domains

Accepted
Partially Accepted
Rejected
Undefined
Free
Approved
Rejected
Order
Characteristic
Continue
Not Applicable
Block on Operation
Block on Completed Operation
Block
Not Applicable

The instrument does not need calibration. No data is entered in the fields related to the calibration.

Time

The instrument is calibrated after a specific time interval. It is selected for calibration on or after the next calibration date.

Number of Times Used

The instrument is calibrated after n time used.

Open

Indicates that the conformance document is created.

Pre-Registered

Indicates that the user has specified a document number against a specific document pack.

Pre-Approved

Indicates that the user approved the conformance document before dispatch of goods.

Not Pre-Approved

Indicates that the user has not approved the document.

Matched (Pre-Inspection)

Indicates that test data lines are created for the specified conformance documents with status Pre-Registered or Pre-Approved.

Matched (Inspection)

Indicates that the conformance document number is specified in the test data lines of the inspection order.

Canceled

Indicates that the document is cancelled.

Manual
System
Fraction

A number with decimals, for example, 3.145.

Integer

An exact whole number as opposed to a number with decimals, for example, 1, 2, or 3.

Option

Values (options) for a characteristic must be defined (for example blue), or red.

First Article Inspection
Certificate of Conformance
Other
Critical
Major
Minor
Not Applicable
Create
Re-use Existing Document
Not Applicable
Standard
Customized
Inspection Order
Certificate of Conformance
Failure Reporting Analysis
Non-Conformance Report
Ship to Stock
Ship to Stock Rule
Corrective Action Plan
First Article Inspection
Root Cause Analysis
Warehouse
Not Applicable
Department
Required

The default status of the FAI document.

In Process

Infor LN populates this status when a order inspection is linked to the FAI.

Approved

Infor LN populates this status when the order inspection is processed and the FAI document is approved.

Failed

Infor LN populates this status if the order inspection is partially accepted or rejected.

Canceled

You can set the status to cancelled when the FAI document is in In Process or Required.

Incomplete
Infor LN populates this status if the form is set to Incomplete using the Set to Incomplete option.
Item

All inventory of each item is combined for inspection.

Warehouse

All inventory of each item/warehouse is combined for inspection.

Location

All inventory of each item/warehouse/warehouse location is combined for inspection.

Lot

All inventory of each item/warehouse/warehouse location/lot is combined for inspection.

Business Partner

Generate storage inspection for the individual lots and/or serial numbers per business partner.

Reduced
Not Applicable
Normal
Tightened
First Article Inspection
Not Blocked

You print the instruments that are not blocked.

Blocked

You print the instruments that are blocked.

All

You print all the instruments.

Tolerance

The limits are entered as percentages of the norm. You can enter the norm in the Norm field.

Value

The limits are entered as values in the Upper Limit field and the Lower Limit field.

Item-Identification
Not Applicable
Item
Order
Upper
Lower
Not Applicable
Characteristic

If this option is selected, you can enter the test data by Characteristic. A reference to a particular quality or distinctive mark of an item or an item part/component. For example, diameter, length, weight.

Sample Part

If this option is selected, you can enter the test data by Sample Part. A part drawn from the item to test it.

Sequence

If this option is selected, you can enter the test data by Sequence. The sequence number of the item on the basis of which characteristics are tested on different samples.

Approved Design
Non-Approved Design
Not Applicable
Add

To generate new order-specific inspection data.

Update

To update order-specific inspection data. The update procedure will first delete the existing inspection data and then generate new inspection data from the master data.

Algorithm

The characteristic value is calculated by means of an algorithm, using by the inspection results of variable or fixed characteristics.

Fixed

he characteristic value is determined once and can be entered in the Fixed Characteristic Value field in the Standard Test Procedure Characteristics (qmptc0115m000) session. LN uses this value to compare to the results entered in the Inspection Order Test Data (qmptc1115m000) session or the Sample Test Data by Serial Number (qmptc1116m000) session.

Variable

The characteristic value is measured immediately by means of an instrument. The results are entered in the Inspection Order Test Data (qmptc1115m000) session or the Sample Test Data by Serial Number (qmptc1116m000) session.

Sales
Storage Inspection
Production (RPT)
Routing (RPT)
Service
Warehouse Transfer
Maintenance Sales
Batch Repair
Maintenance Work
Purchase
Warehouse Transfer (Manual)
Not Applicable
Production (JSC)
Material (BOM)
Routing (TI)
Sales Schedule
Project
Purchase Schedule
Project Contract
EP Distribution
Inventory Inspection
Active

You enter data in the Inspection Order Test Data (qmptc1115m000) session or in the Sample Test Data by Serial Number (qmptc1116m000) session.

Completed

You report inspection order lines completed in the Complete/Process Order Inspections (qmptc1202m000) session.

Free

You generate inspection order lines in the Inspection Order Lines (qmptc1101m000) session.

Printed

You print inspection orders in the Print Inspection Orders (qmptc1400m000) session.

Acceptable

The tested quantity passes the test.

Not Acceptable

The tested quantity does not pass the test.

Xbar and R Control
Not Defined
Xbar and S Control
XM and R Control
Excluding Re-Inspections

Only inspection orders with no originating order specified are considered.

Including Re-Inspections

Only inspection orders with no re-inspection order specified are considered.

Pass

LN decides whether a value is Pass on one of the following conditions: If you entered Integer/Fraction in the Characteristic Type field, and the Measurement Value field is Between Limits or If you entered Option in the Characteristic Type field, and the Option field is Acceptable

Fail

LN decides whether a value is Fail on one of the following conditions: If you entered Integer/Fraction in the Characteristic Type field, and the Measurement Value field is Outside Limits or If you entered Option in the Characteristic Type field, and the Option field is Not Acceptable.

Not Inspected
Qualitative

A value in terms of a description is reported after testing, for example, Acceptable or Not Acceptable, Good or Bad.

Quantitative

A numeric value is reported after testing, for example, 40 (cm).

Free
Active
Completed
Processed
Closed
Purchase (All)
JSC Production
Not Applicable
Routing (TI)
Transfer (Inbound)
Inactive

The line is created. This is the default status.

Active

When the entry criteria condition is met.

Re-Validation

When the criteria for re-validation is met.

Canceled

When the entry criteria is invalid. This status can set the status manually.

Free
Submitted
Released
Expired
Material Line
Incoming Subassembly
Outgoing Subassembly
Activity Line
Not Applicable
Continuous Sampling

This type of sampling only takes place in case of mass production and is used to control processing. After a particular interval, a sample is drawn equally large as the sample size. A decision is taken based on the quality of the sample whether to continue the production or to stop and take corrective action. For this test type, data must be entered in the following fields:

  • - Frequency Unit
  • - Quantity
100

All items are inspected. The sample size and the order quantity have the same value.

Single Sampling

One sample out of the entire order quantity is inspected.

Never

Inspection orders are not updated.

Free

Inspection order with status Free are updated.

Free and Active

Inspection orders with the order status Free and Active are updated. For orders with status Free, only the test data entered is updated.

Analytical

The limits defined for the characteristic cannot be modified in the standard test procedure.

Variable

The limits defined for the characteristic can be modified in the standard test procedure

Norm
Nominal
Not Applicable
New
Not Applicable
Prototype
Overhauled
Repaired
Inspected
Modified
Other