Configuring the Quality Inspections app

To configure the quality inspection app:

  1. Click ln_mob_ap_10_6_a (for IOS) or ln_mob_ap_10_6_b (for Android).
  2. Specify these details:
    Company
    The default company code. This value is defaulted from the LN user data. However, you can modify this value, if required.
    Note: 

    You can specify only one company code at a time.

    Site
    The site of the order inspection.
    Note: 
    • By default, All Sites option is selected. However, you can modify this value.
    • You can select only one site at a time.
    • You can select sites only if the sites are implemented for the specified company.
    • If this value is not specified, all the inspection orders for the specified company are displayed.
    Origins
    The origin of the inspection order. The possible values include all the origins defined in the quality management parameter session in Infor LN.
    Note: 

    You can select multiple origins.

    Warehouses
    The warehouse associated with the inspection order. A warehouse is a place for storing goods.
    Note: 
    • By default, All Warehouses option is selected. However, you can modify this value.
    • You can select multiple warehouses.
    • This field is empty and disabled if only Routing (TI) is selected in the Origin field.

    Work Centers
    The work center associated with the inspection order. A specific production area consists of one or more people and/or machines with identical capabilities, that can be considered as one unit for purposes of the capacity requirement planning and detailed scheduling.
    Note: 
    • By default, All Work Centers option is selected. However, you can modify this value.
    • You can select multiple work centers.
    • This field is empty and disabled, if the value selected in the Origin field is other than Routing (TI).
    Display Period
    The period for which the inspection orders are displayed. The possible options are:
    • Weeks
    • Months
    Only show orders assigned to me
    If this option (toggle) is selected, only the inspection orders that are assigned to the user in the Resource Assignments (qmptc1160m000) session in Infor LN, are displayed.
    Note: 
    • By default, this option (toggle) is selected. However, you can modify the value.
    • If this option (toggle) is not selected, the inspection orders assigned to the user and others are displayed. But, the inspection order that are not assigned to anyone are not displayed.
    Insert default values for measurements/Default norm or nominal values for measurement
    If this option (toggle) is selected, the applicable nominal or norm value (if any) is defaulted when an uninspected test data line is selected.
    Note: 
    • If this option (toggle) is cleared, 0 is defaulted as the nominal or norm value.
    • By default, this option (toggle) is selected. However, you can modify the value.
    Tap on next (Auto save and navigate)
    If this option (toggle) is selected, the inspection order data is saved automatically in case the user does not save the changes before navigating to another inspection order.
    Note: 

    By default, this option (toggle) is selected. However, you can modify the value.

    Camera image quality
    The quality of the image that is captured for the inspection order. The possible options are:
    • Low
    • Medium
    • High
    Note: 
    • This option is only applicable for the uploading of the captured attachments to IDM.
    • By default, the value is set to Low. However, you can modify the value.
    Debug Mode
    If this option (toggle) is selected, the app runs in the debug mode.
    Offline Mode
    If this option (toggle) is selected, you can save the test data Offline. When the device is connected to the internet, you must manually disable the offline mode to synchronize the test data with Infor LN.
    Note: 
    • You can also select this option (toggle) when the device is not connected to the internet.
    • This mode can be used only if the Passcode setting is enabled.
    Passcode setting
    The PIN (Personal Identification Number) to authorize the specifying of the test data in the Offline mode.
  3. Click Done.