Inspection Results by Process Variable (tisfc0134m000)
Use this session to to specify measurement results for the process variables that are linked to an operation (step) of a production order.
- When operation is completed, the total inspected quantity for one process variable cannot exceed total reported quantity of the operation.
- You cannot insert, modify or delete the data if, the
production order is:
- Not released
- Yet to be completed
Field Information
- Production Order
-
The production order's code.
- Operation
-
The sequence number of the operation, which is used for the production of the manufactured subassembly or finished product.
- Operation Step
-
A suboperation connected to a routing operation. An operation step can contain information such as, instructions, process information, and tools information.
- Norm
-
The process variable's target value.
- Upper Control Limit
-
The process variable's upper control limit that is expressed as an absolute value or as a percentage.
Absolute
If the upper control limit is expressed as an absolute value, define the maximum target value of the process variable.
Example
If the target value is 30 and you do not want the upper control limit to exceed 33, enter 33 in this field.
Percentage
If the upper control limit is expressed as a percentage, define the percentage with which the process variable's target value can be exceeded.
Example
If the target value is 30 and you do not want the upper control limit to exceed 33, enter 10% in this field.
- Lower Control Limit
-
The process variable's lower control limit, which is expressed as an absolute value or as a percentage.
Absolute
If the lower control limit is expressed as an absolute value, you must define the minimum value that the process variable's input value can be lower than the target value.
Example
If the target value is 30 and you do not want the lower control limit to be lower than 27, enter 27 in this field.
Percentage
If the lower control limit is expressed as a percentage, define the percentage that the process variable's input value can be lower than the target value.
Example
If the target value is 30 and you do not want the lower control limit to be lower than 27, enter 10% in this field.
- Process Variable
-
The code of the process variable for which the inspection results are specified.
- Sequence Number
-
The sequence number of the process variable.
- Serial Number
-
The item's serial number.
- Inspected Quantity
-
The quantity for which the inspection is completed.
- Inspection Result
-
The inspection results of the process variable.
Note: If the value is less or more than the value specified in the Upper Control Limit and Lower Control Limit, the application displays a warning message.