Production Bill of Material Control (timfc3199m000)

Use this session to define the settings and a template for the production BOM (Production Bill of Materials) that is received from Product Lifecycle Management (PLM) (internal or external).

Note: This session can be accessed only if:
  • The Engineering Revisions check box is selected in the Implemented Software Components (tccom0100s000) session.
  • The Originating App field is set to PLM (Internal) or PLM (external) in the Item Base Data Parameters (tcibd9199m000) session.

Field Information

Introduction Date

The date and time from which the production bill of material control parameters are valid. The parameters are valid up to the effective date of a more recent parameter setting.

Settings
Originating App

Indicates the source from where the production BOMs are received.

Allowed values

EDM
IBD
PLM (Internal)
PLM (external)
Allowed Manual Changes to Production BOM
Add Revision

If this check box is selected, LN allows you to add new revisions manually to a production BOM which originates from PLM. If the origin of production BOM is not PLM, you can always add a revision.

Modify PLM Controlled Fields

If this check box is selected, LN allows you to manually modify the fields that are controlled by PLM based on the template on the production BOMs which originate from PLM. If the origin of production BOM is not PLM, you can always modify the fields in the production BOM.

Add/Delete Material Line

If this check box is selected, LN allows you to manually add or delete the material lines of a production BOM that originates from PLM. If the origin of production BOM is not PLM, you can always add or delete the material lines.

Note: This field is enabled only if the Manual Modify PLM Fields check box is selected.
Add/Delete Alternative Material

If this check box is selected, LN allows you to manually add or delete the alternative materials on a production BOM that originates from PLM. If the origin of production BOM is not PLM, you can always add or delete the alternative materials.

Note: This field is enabled only if the Manual Add/Delete Material Line check box is selected.
Add/Delete Reference Designator

If this check box is selected, LN allows you to manually add or delete the reference designators on a production BOM that originates from PLM. If the origin of production BOM is not PLM, you can always add or delete the reference designators.

Note: This field is enabled only if the Manual Add/Delete Material Line check box is selected.
Received Revision Handling
Automatic Processing

If this check box is selected, the production bill of material (BOM) received from PLM is processed automatically.

Automatic Approving

If this check box is selected, the automatically processed production bill of material (BOM) received from PLM is automatically approved.

Note: This field is enabled only if the Automatic Processing check box is selected.
Print Process Report

If this check box is selected, LN prints a progress report when the production bill of material (BOM) received from PLM is automatically processed.

Note: This field is enabled only if the Automatic Processing check box is selected.
Template
Controlled by PLM
Header
Product

If this check box is selected, the product in the production bill of material header is controlled by PLM.

Source Revision

If this check box is selected, the source revision of the production bill of material is controlled by PLM.

Revision

If this check box is selected, the revision of the production bill of material is controlled by PLM.

BOM Quantity

If this check box is selected, the BOM quantity of the production bill of material (BOM) is controlled by PLM.

Effective Date

If this check box is selected, the effective date of the production bill of material (BOM) is controlled by PLM.

Expiry Date

If this check box is selected, the expiry date of the production bill of material (BOM) is controlled by PLM.

BOM Text

If this check box is selected, the text related to the bill of material (BOM) is controlled by PLM.

Material
Position

If this check box is selected, the position of the material of the bill of material (BOM) is controlled by PLM.

Item

If this check box is selected, the items of the bill of material (BOM) are controlled by PLM.

Net Quantity

If this check box is selected, the net quantity of the materials of the bill of material (BOM) is controlled by PLM.

BOM Unit

If this check box is selected, the unit of the materials of the bill of material (BOM) is controlled by PLM.

Note: 
  • This check box is set if the Net Quantity or the Scrap Quantity check box is selected.
  • This check box is cleared if both the Net Quantity or the Scrap Quantity check boxes are cleared.
Scrap Quantity

Indicates whether the expected scrap quantity of the material is controlled by PLM.

Scrap Percentage

Indicates whether the percentage of the materials that is expected to be scrap, is controlled by PLM.

Length

If this check box is selected, the length of the material associated with the bill of material (BOM) is controlled by PLM.

Width

If this check box is selected, the width of the material associated with the bill of material (BOM) is received from PLM.

Size Unit

If this check box is selected, the size unit of the material associated with the bill of material (BOM) is controlled by PLM.

Number of Units

If this check box is selected, the number of units of the material associated with the bill of material (BOM) is controlled by PLM.

Percentage Required

If this check box is selected, the percentage of the materials required for the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Infor SCM Scheduler check box is selected in the Production Order Parameters (tisfc0100s000) session.
Phantom

If this check box is selected, the phantom indicator in the bill of material (BOM) is controlled by PLM.

Use-Up Item

If this check box is selected, the use-up material of the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Use Up Material check box is selected in the Implemented Software Components (tccom0100s000) session.
Allow Multiple Items

If this check box is selected, multiple items of the bill of material (BOM) are controlled by PLM.

Note: This field is displayed only if the Use Up Material and/ or Alternative Materials check box is selected in the Implemented Software Components (tccom0100s000) session.
Standard Configuration

If this check box is selected, the standard configuration of the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Unit Effectivity check box is selected in the Implemented Software Components (tccom0100s000) session.
Inherit Demand Peg

If this check box is selected, the inherit demand peg indicator of the material is controlled by PLM.

Note: This field is displayed only if the Demand Pegging check box is selected in the Implemented Software Components (tccom0100s000) session.
Material Text

If this check box is selected, the text of the materials associated with the bill of material (BOM) is controlled by PLM.

Alternative Material
Position

If this check box is selected, the position number of the alternative material associated with the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Alternative Materials check box is selected in the Implemented Software Components (tccom0100s000) session.
Priority

If this check box is selected, the priority of the alternative material associated with the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Alternative Materials check box is selected in the Implemented Software Components (tccom0100s000) session.
Alternative Item

If this check box is selected, the alternative item that can be used in the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Alternative Materials check box is selected in the Implemented Software Components (tccom0100s000) session.
Reference Designator
Reference Designator

If this check box is selected, the reference designator that can be used in the bill of material (BOM) is controlled by PLM.

Note: This field is displayed only if the Reference Designators check box is selected in the Implemented Software Components (tccom0100s000) session.
Quantity

If this check box is selected, the quantity of the reference designator that can be used in the bill of material (BOM) is controlled by PLM.

Note: This field is enabled only if the Reference Designators check box is selected in the Implemented Software Components (tccom0100s000) session.