Order Specific Inspection Lines (qmptc0151m000)
Use this session to display or maintain order-specific inspection data lines. For each characteristic or aspect/characteristic combination, an inspection line is available. The data related to this characteristic can be changed for this specific order.
Field Information
- Inspection Sequence
-
The sequence number of the order. For each sequence, one or more samples are drawn to test the characteristics.
- Inspection Line
-
The number that identifies the inspection order line.
- Aspect
- Characteristic
- Characteristic Type
-
The type of value that is measured.
- Unit
-
Note: If you selected Fraction or Integer in the Characteristic Type field, you must fill in the Characteristic Unit field. If you selected Option, the Characteristic Unit field will become blank.
- Characteristic for Algorithm
-
If this check box is selected, this characteristic is used as a variable or constant in the algorithm of another characteristic.
- Option Set
-
Note: You can enter an option set if the Characteristic Type field is on Option.
- Method
-
The type of characteristic value or the way in which the characteristic value is calculated.
- Algorithm
-
Note: You can only enter data in the Algorithm field, if you entered Algorithm in the Method field. Enter the name of the algorithm that is used to calculate the characteristic.
- Test
- Test Area
- Destructive Test
-
If this check box is selected, the test is destructive and the item cannot be used after testing.
If this check box is cleared, the test is not destructive and the item can be used after testing.
- Result Type
-
The type of result reported to the user.
- Test Unit
-
Note: The characteristic unit is the default value. The test unit and the characteristic unit must have the same physical quantity.
- Test Sequence
-
The test sequence specifies the sequence in which the characteristics in a test group are tested. If the value of the Test Sequence field is zero, the sequence of this aspect/characteristic is not important for testing. An aspect/characteristic with a zero test sequence value will be tested after all other tests have taken place.
Example
Destructive Test Test Sequence Test 1 No 1 Test 2 Yes 2 Explanation: The destructive test will take place last.
Note: The sequence number can be the same for more than one characteristic. When this is the case, the tests will be sorted by aspect/characteristic, unless the test sequence number is zero. - Test Standard
-
The standard normally used for the test.
For example, a DIN standard
- Skill
- Employee
-
The person that performs the test on this characteristic.
- Instrument
- Instrument Group
-
The code of the instrument group. The group of instruments with similar characteristics.
- Description
-
The description or name of the code.
- Instrument Number
-
The number of the instrument that can be used to trace the instrument.
- Description
-
The description or name of the code.
- Fixed Characteristic Value
-
A characteristic value that is determined once, and which is compared to the test results entered in the Inspection Order Test Data (qmptc1115m000) session.
Note: This field only applies if the Method field is set to Fixed. - Characteristic Standard
-
The standard normally used for characteristics. This is an informative field.
For example, a DIN standard
- Value Type
-
The value type of the characteristic.
Allowed values
- Norm
- Nominal
- Not Applicable
- Chart Name
-
The code of the chart name to which the nominal values are applicable.
Note: This field is available only if the Nominal option is selected in the Value Type field. - Chart Type
-
The code of the chart type for which the nominal values are applicable.
Note: This field is available only if the Nominal option is selected in the Value Type field. - Tolerance Standard
-
The code of the tolerance standard linked to the nominal value range.
Note: This field is available only if the Nominal option is selected in the Value Type field. - Nominal Value
-
The nominal value of the characteristic, expressed in the characteristic unit.
Note:This field is available only if the Nominal option is selected in the Value Type field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Norm
-
The norm is the desired quality for this characteristic, expressed in the characteristic unit.
Note:This field does not apply if you enter Fixed in the Method field or Option in the Characteristic Type field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Upper Limit
-
The highest characteristic value, expressed in the characteristic unit for which the quality is acceptable.
Note:The Upper Limit field must be greater than or equal to the value in the Norm field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Lower Limit
-
The lowest characteristic value, expressed in the characteristic unit for which the quality is acceptable.
Note:The Lower Limit field must be less than or equal to the value in the Norm field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Origin
- Inspection Line
-
The number of the order line to which the inspection order applies. This can be the position of the sales order line, the position of the purchase order line, or the position of the estimated materials.
- Defect Classification
-
The severity of the defect.
Allowed values
- Critical
- Major
- Minor
- Not Applicable
- Reference Designator
-
The location where the item component can be inserted. This value is used to differentiate between two test group lines with the same data.
Note: You can select this value from the Reference Designators (tcmcs0190m000) or the Standard Test Procedure Characteristics (qmptc0115m000) session. - Operation
-
A quality inspection must take place, during or after this operation.
- Ignore for Result Determination
- If this check box is selected, the characteristic
is not considered when determining the inspection result.Note: This setting is defaulted from the Standard Test Procedure Characteristics (qmptc0115m000) session based on the selected Characteristic. Else, the modified setting from the Characteristics (qmptc0101m000) session is considered for lines that are created manually.