Test Group Characteristics (qmptc0137m000)
Use this session to create and maintain test group characteristics for a specified standard test procedure.
Field Information
- Standard Test Procedure
-
The code of the standard test procedure.
- Description
-
The description or name of the code.
- Version
-
The version number of the standard test procedure. If you duplicate the standard test procedure, LN assigns a new version number.
- Test Group Number
-
The test group number.
- Test Group
-
The code of the test group.
- Description
-
The description or name of the code.
- Test Type
-
The method by which the samples are taken from the order quantity.
Allowed values
- Continuous Sampling
-
This type of sampling only takes place in case of mass production and is used to control processing. After a particular interval, a sample is drawn equally large as the sample size. A decision is taken based on the quality of the sample whether to continue the production or to stop and take corrective action. For this test type, data must be entered in the following fields:
- - Frequency Unit
- - Quantity
- 100
-
All items are inspected. The sample size and the order quantity have the same value.
- Single Sampling
-
One sample out of the entire order quantity is inspected.
- Sampling Rule
-
The sampling rule related to the test group.
Note: This field is available only if the Test Type is set to Sampling Rule. - Team
-
The code of the team which executes the test or is responsible for the test group.
- Aspect
-
The code of the aspects.
Note: You can select this value from the Aspects (qmptc0102m000) or the Standard Test Procedure Characteristics (qmptc0115m000) session. - Description
-
The description or name of the code.
- Characteristic
-
The code of the characteristic.
Note: You can select this value from the Characteristics (qmptc0101m000) or the Standard Test Procedure Characteristics (qmptc0115m000) session. - Description
-
The description or name of the code.
- Reference Designator
-
The location where the item component can be inserted. This value is used to differentiate between two test group lines with the same data.
Note: You can select this value from the Reference Designators (tcmcs0190m000) or the Standard Test Procedure Characteristics (qmptc0115m000) session. - Description
-
The description or name of the code.
- Defect Classification
-
The severity of the defect.
Allowed values
- Critical
- Major
- Minor
- Not Applicable
- Test Sequence
-
The sequence in which the characteristics are tested.
- Characteristic Usage
-
The usage type of the characteristic.
Allowed values
- Analytical
-
The limits defined for the characteristic cannot be modified in the standard test procedure.
- Variable
-
The limits defined for the characteristic can be modified in the standard test procedure
- Limit
-
The value at which the quality of the characteristic is accepted. This value is expressed in the characteristic unit.
- Lower Limit
-
The minimum value of the norm value up to which the quality of the characteristic is acceptable. The value is expressed in characteristic unit.
- Upper Limit
-
The maximum value of the norm value up to which the quality of the characteristic is acceptable. The value is expressed in characteristic unit.
- Option Set
-