Inspection Orders (qmptc2100m100)

Use this session to define and modify storage inspection orders for an item.

Field Information

Order

inspection order

Standard Test Procedure

quality ID

Test Group

test group

Test Type

Specification of how samples are taken from the order quantity.

Allowed values

Continuous Sampling

This type of sampling only takes place in case of mass production and is used to control processing. After a particular interval, a sample is drawn equally large as the sample size. A decision is taken based on the quality of the sample whether to continue the production or to stop and take corrective action. For this test type, data must be entered in the following fields:

  • - Frequency Unit
  • - Quantity
100

All items are inspected. The sample size and the order quantity have the same value.

Single Sampling

One sample out of the entire order quantity is inspected.

Frequency

frequency

Note: You cannot continue the inspection procedure when your order quantity is less than the frequency quantity (for example, when your order quantity is 40, and your frequency quantity is 50). In such a case, no samples can be generated, and you must decrease the frequency quantity.
Frequency Unit

frequency unit

Note: The frequency unit and the unit of the order quantity do not have to be identical. However, when they are not identical a correct conversion factor is essential.
Percentage

The sample size is the total quantity that is to be tested. In this field, the sample size is expressed as a percentage of either the order quantity or the frequency (in case you selected Continuous Sampling as the test type).

Sample Size

The sample size is the total quantity of all samples which are to be tested out of the order quantity, expressed in the unit of the sample size. In this field, it is expressed as a fixed quantity.

Sample Unit

The unit of the sample size.

Owner