BOD Parameters (tlbct6100m000)

Use this session to set the BOD Parameters for the new ION Connectivity framework.

The new connectivity is used only if parameter “Is IMS Active” is set. By default, it is not set, meaning that the ‘old’ framework (where ION starts the bshells that processes the inbound BODs and polls for outbound BODs) is used.

Field Information

Is IMS Enabled

If this check box is selected, IMS is enabled as interface between ION and LN for BOD handling.

Is IMS Active

If this check box is selected, IMS is used as interface between ION and LN.

Pause Sending BODs by IMS

If this check box is selected, no BODs to ION are published using IMS in LN. This prevents waste of resources when ION is not ready to receive BODs.

Number of Publishers

The maximum number of publishers that will be run simultaneously. Publishers publish BODs from all companies together.

Cleanup History Messages after

Specifies the number of days that BOD messages with status other than "Error" are kept in the history tables after they are removed from the Inbox and Outbox. If 0 is specified, no history is kept.

Cleanup History Error Messages after

Specifies the number of days that BOD messages with the status "Error" are kept in the history tables after they are removed from the Inbox and Outbox. If 0 is specified, no history is kept.