Inspection Order Lines (qmptc1101m000)
Use this session to maintain inspection order lines. For each combination of an aspect and a characteristic, an inspection line is available. The data related to the characteristic can be changed for this specific inspection order.
You cannot modify a record if the test data of the line already exists. If the order line status is set to Completed no new lines can be added for this origin order.
You can view the transaction events related to a specific item, serial or lot combination for an inspection order, order inspection and non-conformance reports in the Item, Lot and Serial Transactions (whltc3510m000) session of Warehousing.
Tabs
- General Details about the characteristic.
- Test Data Details about the method of testing.
Field Information
- Inspection Order
- Line
-
The position number on the order to which the inspection order is linked. This can be the position number of the sales order line, the position number of the purchase order line, or the position number in the BOM.
- Status
-
The order line status indicates the current status of the inspection line.
The status is changed in several sessions:
- Inspection Order Lines (qmptc1101m000) (free)
- Print Inspection Orders (qmptc1400m000) (printed)
- Inspection Order Test Data (qmptc1115m000) (active)
- Complete/Process Order Inspections (qmptc1202m000) (completed)
- Planned Start Date
-
The planned date on which the user initiates the inspection of the characteristic.
- Planned Completion Date
-
The planned date for the completion of the inspection of the characteristic.
- Aspect
-
aspects
- Characteristic
-
characteristic
Note:Infor LN defaults this value based on the value specified in the Document field.
This field is enabled only if the Conformance Reporting check box is cleared for the related inspection order.
- Document
-
The document associated with the conformance reporting.
Note:This field is enabled only if the Business Communication Implemented check box is selected in the Quality Management Parameters (qmptc0100m000) session.
Infor LN populates the value in this field from the Quality Documents (tcbcm0120m100) only if the Conformance Reporting check box is selected.
- Reference Designator
-
The location where the item component can be inserted. This value is used to differentiate between two test group lines with the same data.
Note: You can select this value from the Reference Designators (tcmcs0190m000) or the Standard Test Procedure Characteristics (qmptc0115m000) session. - Defect Classification
-
The severity of the defect.
Allowed values
- Critical
- Major
- Minor
- Not Applicable
- Characteristic Type
-
The type of value that is measured.
- Characteristic Unit
-
algorithm
Note: You can use the Algorithm field, only if you enter Algorithm in the Method field. Enter the name of the algorithm which will calculate the characteristic. - Characteristic for Algorithm
-
If this check box is selected, this characteristic can be used as a variable or as a constant in the algorithm of another characteristic.
- Option Set
-
Note: You can enter an option set if the Characteristic Type field is on Option.
- Method
-
The type of characteristic value or the way in which the characteristic value is calculated.
- Algorithm
-
algorithm
Note: You can use the Algorithm field, only if you enter Algorithm in the Method field. Enter the name of the algorithm which will calculate the characteristic. - Actual Start Date
-
The date on which the first data is entered for the inspection order line. This date is updated in the Inspection Order Test Data (qmptc1115m000) session and cannot be modified.
- Actual Completion Date
-
The date on which the inspection is reported as completed. This date is updated in the Complete/Process Order Inspections (qmptc1202m000) session, and cannot be modified.
- Test
-
test
- Test Area
-
test areas
- Destructive Test
-
If this check box is selected, the test is destructive and the item cannot be used after testing.
- Result Type
-
The type of result reported to the user.
- Test Unit
-
test unit
Note: The characteristic unit is the default value. The test unit and the characteristic unit must have the same physical quantity. - Test Standard
-
The standard normally used for the test. For example, a DIN standard.
- Skill
-
skill
- Employee
-
The person that performs the test on this characteristic.
- Instrument
-
instrument
- Instrument Group
-
The code of the instrument group. The group of instruments with similar characteristics.
- Description
-
The description or name of the code.
- Instrument Number
-
The number of the instrument that can be used to trace the instrument.
- Description
-
The description or name of the code.
- Fixed Characteristic Value
-
A characteristic value that is determined once. A characteristic value that is determined once.
Note:The fixed characteristic value is compared to the test results entered in Inspection Order Test Data (qmptc1115m000) session.
This field only applies if the Method field is set to Fixed. If the Characteristic Type field is set to Integer, the Fixed Characteristic Value field is rounded off to the nearest integer.
Note:User entry Rounded value 5 11 4 10 6 11 - Characteristic Standard
-
The standard normally used for characteristics.
For example, a DIN standard
- Value Type
-
The value type of the characteristic.
Allowed values
- Norm
- Nominal
- Not Applicable
- Chart Name
-
The code of the chart name to which the nominal values are applicable.
Note: This field is available only if the Nominal option is selected in the Value Type field. - Chart Type
-
The code of the chart type for which the nominal values are applicable.
Note: This field is available only if the Nominal option is selected in the Value Type field. - Tolerance Standard
-
The code of the tolerance standard linked to the nominal value range.
Note: This field is available only if the Nominal option is selected in the Value Type field. - Nominal Value
-
The nominal value of the characteristic, expressed in the characteristic unit.
Note:This field is available only if the Nominal option is selected in the Value Type field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Norm
-
The norm is the desired quality for this characteristic, expressed in the characteristic unit.
Note:This field does not apply if you enter Fixed in the Method field or Option in the Characteristic Type field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Upper Limit
-
Type in the highest characteristic value, expressed in the characteristic unit, for which the quality is acceptable.
Note:The Upper Limit field must be greater than or equal to the value in the Norm field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.
- Lower Limit
-
Type in the lowest characteristic value, expressed in the characteristic unit, for which the quality is acceptable.
Note:The Lower Limit field must be greater than or equal to the value in the Norm field.
You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.
In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.