Order Specific Inspection Lines (qmptc0151m000)

Use this session to display or maintain order-specific inspection data lines. For each characteristic or aspect/characteristic combination, an inspection line is available. The data related to this characteristic can be changed for this specific order.

Field Information

Inspection Sequence

The sequence number of the order. For each sequence, one or more samples are drawn to test the characteristics.

Inspection Line

The number that identifies the inspection order line.

Aspect

aspects

Characteristic

characteristic

Characteristic Type

The type of value that is measured.

Unit

characteristic unit

Note: If you selected Fraction or Integer in the Characteristic Type field, you must fill in the Characteristic Unit field. If you selected Option, the Characteristic Unit field will become blank.
Characteristic for Algorithm

If this check box is selected, this characteristic is used as a variable or constant in the algorithm of another characteristic.

Option Set

option set

Note: You can enter an option set if the Characteristic Type field is on Option.
Method

The type of characteristic value or the way in which the characteristic value is calculated.

Algorithm

algorithm

Note: You can only enter data in the Algorithm field, if you entered Algorithm in the Method field. Enter the name of the algorithm that is used to calculate the characteristic.
Test

test

Test Area

test areas

Destructive Test

If this check box is selected, the test is destructive and the item cannot be used after testing.

If this check box is cleared, the test is not destructive and the item can be used after testing.

Result Type

The type of result reported to the user.

Test Unit

test unit

Note: The characteristic unit is the default value. The test unit and the characteristic unit must have the same physical quantity.
Test Sequence

The test sequence specifies the sequence in which the characteristics in a test group are tested. If the value of the Test Sequence field is zero, the sequence of this aspect/characteristic is not important for testing. An aspect/characteristic with a zero test sequence value will be tested after all other tests have taken place.

Example

  Destructive Test Test Sequence
Test 1 No 1
Test 2 Yes 2

Explanation: The destructive test will take place last.

Note: The sequence number can be the same for more than one characteristic. When this is the case, the tests will be sorted by aspect/characteristic, unless the test sequence number is zero.
Test Standard

The standard normally used for the test.

For example, a DIN standard

Skill

skill

Employee

The person that performs the test on this characteristic.

Instrument

instrument

Instrument Group

The code of the instrument group. The group of instruments with similar characteristics.

Description

The description or name of the code.

Instrument Number

The number of the instrument that can be used to trace the instrument.

Description

The description or name of the code.

Fixed Characteristic Value

A characteristic value that is determined once, and which is compared to the test results entered in the Inspection Order Test Data (qmptc1115m000) session.

Note: This field only applies if the Method field is set to Fixed.
Characteristic Standard

The standard normally used for characteristics. This is an informative field.

For example, a DIN standard

Value Type

The value type of the characteristic.

Allowed values

Norm
Nominal
Not Applicable
Chart Name

The code of the chart name to which the nominal values are applicable.

Note: This field is available only if the Nominal option is selected in the Value Type field.
Chart Type

The code of the chart type for which the nominal values are applicable.

Note: This field is available only if the Nominal option is selected in the Value Type field.
Tolerance Standard

The code of the tolerance standard linked to the nominal value range.

Note: This field is available only if the Nominal option is selected in the Value Type field.
Nominal Value

The nominal value of the characteristic, expressed in the characteristic unit.

Note: 

This field is available only if the Nominal option is selected in the Value Type field.

You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.

In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.

Norm

The norm is the desired quality for this characteristic, expressed in the characteristic unit.

Note: 

This field does not apply if you enter Fixed in the Method field or Option in the Characteristic Type field.

You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.

In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.

Upper Limit

The highest characteristic value, expressed in the characteristic unit for which the quality is acceptable.

Note: 

The Upper Limit field must be greater than or equal to the value in the Norm field.

You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.

In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.

Lower Limit

The lowest characteristic value, expressed in the characteristic unit for which the quality is acceptable.

Note: 

The Lower Limit field must be less than or equal to the value in the Norm field.

You can specify the value in this field, if the Characteristic Type field is set to Option and this value is not used to determine the inspection result.

In case of qualitative test entry ( Result Type is Qualitative for the related inspection order line), this value is used only to display the information and is not used to determine the inspection results.

Origin

origin

Inspection Line

The number of the order line to which the inspection order applies. This can be the position of the sales order line, the position of the purchase order line, or the position of the estimated materials.

Defect Classification

The severity of the defect.

Allowed values

Critical
Major
Minor
Not Applicable
Reference Designator

The location where the item component can be inserted. This value is used to differentiate between two test group lines with the same data.

Note: You can select this value from the Reference Designators (tcmcs0190m000) or the Standard Test Procedure Characteristics (qmptc0115m000) session.
Operation

operation

A quality inspection must take place, during or after this operation.