Preferences & Integrations
Preferences are set to control the way the PLM and CAD Connectors work. Administrators can set the Preference Authorizations based on the Organizational need.
Each preference in PLM can have one of the authorizations, Admin or User.
: The value for this preference is same across the organization for all users and only Administrators can update these values. Users can only view and use these values.
: The value for this preference can be specific to each user and a user can maintain the values as per the requirement.
As part of new company, default authorizations are provided. As per the organization needs, Administrators can change the authorization using the Preferences Metadata (pdadm0101m000) session.
This is applicable to PLM Preferences and CAD Preferences.
For example, the Classification Parameters and Permission set to
.Administrators can change this to
if required.As another example, in the below screen, the Permissions of the Inventor Initial Save Options can be reviewed and changed accordingly.
In the Preferences Metadata (pdadm0101m000) session, you can search the specific Preference and change it accordingly.
To set the actual value of the preference, there are 3 types of sessions:
- : This type of session is used by Administrators to set/update the preference value which has permission type Admin.
- : This type of session is used by Administrators to update the values of the User preferences for any user. For example, Administrator can change the path of edit location for u1, u2 and u3 users. These are preferences which have User Permission, that is, the Administrator can modify preferences of any user.
- : Using this type of session, a user can update the values of the preferences which has User permissions. These preferences are specific to the user.
A specific session for each CAD Connector is provided for updating and reviewing CAD Connector Preferences. This table lists the preferences sessions:
Application | All User Preferences | User Preferences | My Preferences |
---|---|---|---|
PLM | pdadm0102m300 | pdadm0102m200 | pdadm0102m100 |
Toolkit | pdcad0101m200 | pdcad0101m300 | pdcad0101m100 |
AutoCAD | pdcad0102m100 | pdcad0102m200 | pdcad0102m000 |
Catia | pdcad0103m100 | pdcad0103m300 | pdcad0103m000 |
Inventor | pdcad0105m100 | pdcad0105m200 | pdcad0105m000 |
MS Office | pdcad0107m100 | pdcad0107m200 | pdcad0107m000 |
Creo | pdcad0108m100 | pdcad0108m200 | pdcad0108m000 |
Solid Edge | pdcad0109m100 | pdcad0109m200 | pdcad0109m000 |
Solid Works | pdcad0110m100 | pdcad0110m200 | pdcad0110m000 |
UG | pdcad0111m200 | pdcad0111m300 | pdcad0111m000 |
Each user must be assigned to a Default Project in the preferences before the user can start working with the application.
The user can set the Default Project using the My Preferences as shown here:
Administrator can also set the Default Project for a user using the User Preferences.