Performing a conversion to runtime - On-premises

  1. To avoid problems with locked tables, ensure that all users have signed out from LN before the conversion starts.
  2. Perform the conversion.
    1. Start the Convert To Runtime dialog box.
    2. Specify the appropriate ranges and indicate which components must be converted.
      Note: 
      • If the Tables check box is selected, only the table definitions are created, not the tables themselves. To create the tables, use the Create Tables dialog box.
      • If the Reconfigure Tables check box is selected, the system reconfigures all changed tables. The range of tables is not taken into account. Tables are reconfigured for the companies linked to the specified range of package combinations.
    3. Click Convert to Runtime.

      The output of the reconfiguring process is logged in the $BSE/log/log.reconfig file.

      If the reconfiguration of the tables is not successful, for example because of lock errors, this question is displayed: Error during file configuration; try again?. In that situation, complete these steps to resolve the problem:

      1. To stop the process, click No in the message box.
      2. Ensure that everybody has signed out from LN.
      3. Start the Application Locks (ttadv9598m000) session and remove the application locks that start with "ttadv502" and contain the code of your package combination.
      4. Restart the Convert To Runtime dialog box and restart the reconfiguration of the tables.
      5. After the conversion has been finished, ensure that all users restart their bshells. This is to avoid errors within those bshells.