Check Integrity (BSE) environment

Check if all (pending) program domains and table definitions are converted to runtime, and if all LN tables are correctly reconfigured. Run these sessions:

  • All table fields defined within the session Binary Table Fields (ttaad2142m000) must be of datatype raw. The active indicator must be selected for all tables.

  • Create Runtime Data Dictionary for Infor LN Server (ttadv5213m000). Select the Also dump data definitions check box. This is to actualize the tools data dictionary.
  • Create Runtime Data Dictionary (ttadv5210m000). Select at least the Domains, Tables, and Reconfigure Tables check boxes (for all package combinations). This is to actualize the application data dictionary.
  • Check Tables (ttaad4232m000) to validate the table consistency.
  • Validate Data Integrity (ttaad4233m000). Clear the check boxes related with high ASCII to validate the integrity of the data.
Note: Correct all signaled errors. Data integrity issues must be corrected as much as possible.