| Activate sites - Activating the Sites parameterThe final stage in the activation process is the actual multisite activation. You can only execute this stage if: - You have super user authorization.
- The activation status is In Preparation.
Before launching the activation: - Complete and successfully validate the setup in the In Preparation stage.
- It is strongly recommended to create a backup of the company
environment.
To activate the multisite concept: Click Activate on the Sites tab in the Multisite Concepts Activation (tcemm4600m000) workbench session. Click Yes in the dialog box displaying the message: "This
step will lock the companies to start the Data Upgrade Run. Do you want to
continue?" Note:
Locking the companies means that the sessions of the company environment are
unavailable for end users during the execution of the process. In the Initialize Data Upgrade Run (ttspt2200m000) session that starts, specify the settings
for the data upgrade run. - To immediately start the data upgrade run, select the Start Data Upgrade Engine After Initialization and
click Initialize. See step 8 for the steps carried out during
the data upgrade run.
- Otherwise, clear this check box and see next
step.
Click Initialize to complete the creation of the data upgrade
run and close the Initialize Data Upgrade Run (ttspt2200m000) session. - Start the Data Upgrade Runs (ttspt2500m000) session.
- Select the data upgrade run created in the previous steps and
if required, adjust the settings.
In the appropriate menu, select Data Upgrade Engine. In the Data Upgrade Engine (ttspt2201m000) session that opens, check the run settings if required
and click Continue to start the data upgrade run. You can run
the process in simulation mode first. The data upgrade run includes these steps: - Revalidate the master data setup.
- Add sites to operational data such as orders, quotations,
claims, shipments, and so on, that are not stored in history tables.
- Set the Sites concept to Active in
the Multisite Concepts Activation (tcemm4600m000) workbench session.
Unlock the sessions of the company environment. Note:
This means that from this step onward, end users can resume working in the
company environment. - Assign sites to history data, that is, orders, shipments,
quotations, and so on that are present in history tables.
Note In case of errors during the revalidation of the master data
setup, an error report is created and the process stops. You must manually
correct the errors and restart the data upgrade run starting the Data Upgrade Runs (ttspt2500m000) session and clicking Data Upgrade Engine. | |