| Implementing FMEAStep 1. In the FMEA Generation Structure (qmpqm1100m000) session, you must link a system to a
specified system, or a subsystem, and a fault. Note: You can specify
either a system, a subsystem or both. You must specify a fault. Click Generate to generate the FMEA number for the specified
structure. However, if the Generated check box is selected, a FMEA number
already exists for the structure. Note:
Click Browse to view all the FMEAs generated for a fault associated with a
structure. Step 2. In the Failure Modes and Effects Analysis (qmpqm1620m000) session, for the FMEA number,
specify: - The description of the failure.
- The module against which the faults are being analyzed. You
can also link an item to the module. Specify the potential failure mode and
effects of the failure.
- On the Failure Resolution tab, specify the causes that can
be attributed to the failure. Specify the occurrence code, detection code and
the severity ranking for the fault. The application calculates the Risk
Priority Number(RPN) based on the values specified.
- From the Actions menu, set the status of the FMEA to In
Progress.
- Click on the failure resolution line to access the Failure
Resolution (qmpqm1140m100) session.
Step 3. In the Failure Resolution (qmpqm1140m100) session: - If an action must be executed, specify a description in the
Recommended Action field. You must specify the values for the new severity,
occurrence, and detection rankings. The application calculates the new RPN for
the action taken.
- If no action is required, you must specify the same values
in the New Rankings fields as specified in the Current Rankings
fields.
Note: If
a new resolution is specified, enter a description in the Current Controls,
Recommended Actions, Potential Causes and Action Taken fields, . Step 4. In the Failure Modes and Effects Analysis (qmpqm1620m000) session: - In the Failure Resolution tab, set the status of the
Action Taken field on the Resolution lines to Accepted or Not Accepted. Note: It is recommended
that you Accept the Failure Resolution line for which a new failure resolution
is specified and the RPN value is reduced.
- Set the status of the FMEA to Closed. Note: You cannot Close the
FMEA if any of the failure resolution lines have the status Pending.
Step 5. In the Delete Failure Modes and Effects Analysis Reports
(qmpqm1220m000) session, you can move the FMEA with the status Close/Cancelled
to history by deleting the specified records. | |