Modelo de dados do usuário (ttams1110m000)

Use this session to define a template with the default settings and parameters that are valid for a group of LN users. This template can be linked to a user in the Dados do usuário (ttaad2500m000) session and the Atribuir funções e modelos a usuários (ttams1201m000) session.

By using the Visualizações, Referências o Ações menu, you can convert the changes in the user data template to the data dictionary. The user file u<user_name> in the directory $BSE/lib/user is (re)build for all users in the specified range in the Converter alterações para DD de runtime (ttams2200m000) session. You must restart Tools to make the changes active at runtime.

Tópico relacionados

 

Código do modelo
The code of the user data template.
Servidor de aplicativo
The server between the user interface and the application logic. The user interface connects to the application logic by using this server. The default server is bshell, which can be found in the ${BSE}/lib/ipc_info file. This field can be left empty if the application logic and user interface are located on the same system, and the application server in ipc_info is bshell.

The user interface and application logic can also be located on different systems. In that case, you must specify the system on which the server can be found and the server as defined in the ${BSE}/lib/ipc_info file of that remote system. The system name is placed before the application server name, separated by an exclamation mark (!).

If the application logic is placed on host2, you must enter: host2!<application_server>.

Exemplo

localremote
host1host2
User Interface--->Applic. Logic (bshell)

 

LOCAL (host1): Application Server: host2!bshell

REMOTE (host2): ${BSE}/lib/ipc_info: bshell s 0 0 s ${BSE}/bin/bshell6.2

Result: The user interface of host1 will communicate with ${BSE}/bin/bshell6.2 on host2.

Sistema de inicialização
The system from which the user starts the application. This is also the system to which the remote user file is dumped when this file is created on another system or workstation.
Sistema de inicialização 2
The second system from which the user, linked to the user data template, can start the application. For example, if the first startup system is down or temporarily not available. This is also a system on which the remote user file is dumped when this file is created on another system or workstation.
Caminho para os arquivos da Ajuda/Servidor de Ajuda
The path to the virtual folder where the Infor ES Web UI is installed. For example: "srv-nld-beem/webtop".
Imprimir tempo de atraso da exclusão (h)
The time between handling a print request and deleting the temporary file. The temporary file stores the data for a period of time before the text is printed. The entered value is used by default when a print program is started.
Local
The name of the Tools Super Set locale. A locale is a collection of the TSS character set definition, the NLS locale for the system and minimum and maximum values for form and database fields. Each locale uses a specific range of (multi-byte) characters of the Tools Super Set (TSS).
Intervalo de atualização [seg.]
The period after which the data of a record is refreshed. If you enter the value 0 seconds, the data of the records will not be refreshed.
Nota

You can also refresh the data on a form by using the Refresh command on the Visualizar menu.

Histórico de sessões de registro
If this check box is selected, Tools maintains a history log file. A history of session usage can be built up by user, linked to a user template. The history is stored in the file $BSE/lib/TIME.HIS. For each user, the history contains a list of the used sessions, with the execution and termination date and time. The history can be printed using the Imprimir histórico de usuários (ttaad2402m000) session. To delete the history, run the Excluir histórico do usuário (ttaad2202m000) session.

Clear the history log file regularly, and select this field only if absolutely necessary.

Fuso horário
The time zone in which the user, linked to the user data template, is located.
Dispositivo padrão de relatório externo
The default device for external reporting. This device is used if an external reporting tool is used and the report is available on the report server. If this field is empty, the default device specified in the Configurações de impressão do WebUI (ttaad3108m000) session is used.
Hora inicial
The beginning of the time interval in which the users, that are linked to the user data template, are authorized to start Tools.
Hora final
The end of the time interval in which the users, that are linked to the user data template, are authorized to start Tools.
Tipo de comando shell
Specifies whether the LN user, linked to the user data template, can branch to a session or a shell.
Comando shell
The shell that is used to start an external program.

If the command type is UNIX, you can enter a UNIX program. For example, ksh.

If the command type is Session, you can enter a session or menu code. For example, ttstpshell or mtttls1000m0001.

Perm. exec. progr. por cód. sessão
If this check box is selected, the user that is linked to the user data template can start a session or menu by using the Run Program command on the Ferramentas menu in Web UI or Worktop.
Permitir personalização do aplicativo
If this check box is selected, the users, which are linked to the user data template, are authorized to personalize the form layout of LN sessions.

In both the Worktop and the Web UI, the users can customize the grid (columns) in overview sessions. In the Web UI, the users can also hide/unhide fields and change field labels in other session types.

For more information, refer to:

  • To personalize ERP LN in the Web Help
  • Personalize ERP sessions in the Web UI online help

If this check box is cleared, the users cannot personalize the form layout of LN sessions.

Gerenciar mensagens suprimidas
If this check box is selected, the user is allowed to suppress messages of type “Information”. In each information message dialog, a Do not show this message again check box is displayed. To suppress a message, the user must select this check box and click OK.

The suppressed message settings are stored as personalizations for the user. Authorized users can distribute these settings to, for example, a company number or to all users. See Personalizações de sessão (ttadv9100m000).

Nota

Suppressing messages is only possible if the Suppress Messages parameter is enabled. See Parâmetros de ferramentas (ttaad0100m000).

If this check box is cleared, the user cannot suppress messages. The Do not show this message again check box is not displayed.

Seleção permitida de Gerenciar perguntas memorizadas
If this check box is selected, the user is allowed to suppress questions. In each question dialog, a Do not show this question again check box is displayed. To suppress a question, the user must select this check box and click the desired answer button.

The suppressed question settings are stored as personalizations for the user. Authorized users can distribute these settings to, for example, a company number or to all users. See Personalizações de sessão (ttadv9100m000).

Nota

Suppressing questions is only possible if the Enable Remember Question Selection parameter is enabled. See Parâmetros de ferramentas (ttaad0100m000).

If this check box is cleared, the user cannot suppress questions. The Do not show this question again check box is not displayed.

Autorização para todos os dispositivos
If this check box is selected, the user, linked to the user data template, is authorized to print reports on all devices.

If this check box is cleared, the user is not authorized to print reports on devices unless they are defined in the Modelo de preferência do dispositivo (ttams1140m000) session.

Permitir alteração de idiomas de dados
If this check box is selected, the users, which are linked to the user data template, are authorized to switch to another data language. In this way, users can view and edit data in multiple languages in sessions that are multilanguage enabled.

If this check box is cleared, the users can only view data in their default data language, which is defined in the Idiomas de dados field in the Dados do usuário (ttaad2500m000) details session.

See Multilanguage application data.

Permitir uso do operador OR no filtro avançado
This option is only visible if the “Allow use of OR Operator” is enabled on the Parâmetros de ferramentas (ttaad0100m000) session.

If this check box is selected, the “Or” search operator can be specified within Filtering by the user, linked to the user data template.

If this check box is cleared, the “Or” search operator cannot be specified. If a filter uses an “Or” search operator, the user is allowed to only run the filter if it is a published filter. This setting is valid when the user runtime files are rewritten after running the Convert TSS Data to Runtime.