User Data (ttams1100s000)

Use this session to specify the system data, defaults settings, authorizations, and templates applicable for the Infor LN user. The data is necessary for the user to start up a Tools application successfully. In this session you can also specify the Tools user's address data. For example, the e-mail address, telephone number, fax number, and so on.

If you have specified the data for the Tools user, click Close to return to the overview session. Use the commands on the Vues, Références ou Actions menu to create the user file in Tools.

Remarque

A textgroup authorization template must be specified for a normal user, otherwise the user is unable to read or write text in Tools.

 

Utilisateur
A user code to identify the user as an Infor LN user.

The Tools user code is normally similar to the user code specified in the Code d'accès système field. However, you can specify more than one Tools user for one system logon.

When a user starts the bshell, by default the system starts with the Tools user code that is equal to the system logon code. You can start the bshell with a different Tools user code by setting the User environment variable.

Exemple

System logonInfor LN user
davedave
davedave_01
davedave_02
johnjohn
johnjohn_01

 

If the user with the system logon dave starts the bshell, by default he will be user dave in Tools. The user dave can fill the environment variable User with dave_01 or dave_02, to start as another Tools User.

If the user with the system logon dave sets the environment variable USER to john or john_01 and tries to start the bshell, the message Not authorized to run as user john appears. In the same way, UNIX user john can only start the bshell as Tools User john or john_01, but not as dave, dave_01 or dave_02.

Remarque

After running the Changement de la longueur des noms util. syst. d'expl. (ttaad2220m000) session, a one-to-one relationship exists between system login and Infor LN User. You can link each system login to only one Infor LN user.

Nom
The name of the Tools user.
Utilisateur Infor Security
This field is displayed only if the SSO actif check box in the Paramètres SSO (ttams0100m000) session is selected. Specify the name of the user as it is known in SSO Service.

You can leave the SSO User field empty. In that case the value of the Code d'accès système field is used during the Convert to Runtime. The Infor SSO User must be unique; for example, an Infor SSO User can only be specified for one Infor LN user.

During the convert to runtime this field is dumped into the u<user> file with the sso_user tag.

Also a $BSE/lib/user/sso/s<SSO_USER> file, that contains the Application User name, is created. The format is baanuser:<baan user name>. This file is used by the Bshell to make the mapping from SSO user to Application User.

To prevent that an end user can tamper with the configuration to get more credentials, an extra file $BSE/lib/sso.permissions is introduced for BLogin. This file contains the permissions for SSO users to impersonate a certain OS user. The file is to be maintained by the system administrator and must only be writable on OS level by the system administrator. It must be considered as having the same security status as for example the OS password file. If this file does not exist, BLogin refuses to handle SSO requests.

Utiliser l'utilisateur système générique
If this check box is selected, the default OS-user identity that is used in SSO mode to run the binaries will be displayed. Any user can impersonate the Generic System User. After conversion this data is placed into the sso_config file as generic_user:<Generic User>.

The Utiliser l'utilisateur système générique field is enabled if the Annul. util. syst. autorisé check box in the Paramètres SSO (ttams0100m000) session is selected.

Code d'accès système
The Code d'accès système code of the user. The user code specified in the Utilisateur field is used as the default.

Before installing Tools, a number of system logons have to be created by the system manager by using a system administration program.

Tools checks if the logon code specified in this field exists in the password file. If not, a warning appears.

Important

You can only specify system login codes that are in lower case.

Note that the System Login field will be disabled when the Use Generic System User field is checked. This is the case when SSO is activated. The value of the displayed Generic System User field will than be used during Convert to Runtime.

Type d'utilisateur
The user type for the Infor LN user.
Combinaison d'applications
The user's package combination of the Tools software.
Package Combination
The description of the package combination.
Société
The default company that contains data that the Infor LN user will work with.

Access to a company is only possible if the package combination of the Tools user and company are the same.

There are exceptions to this rule. The company's package combination can only differ from the user's package combination under the following restrictions:

  • Both package combinations must include the same library authorizations.
  • The package VRCs in both package combinations can only be different if both package VRCs are derived from each other, or both package VRCs are derived from the same package VRC, and no changes in data definitions or domains have been made in the derived package VRCs.
Remarque

If the user is a normal user, the company authorization for the specified company is automatically generated.

Rubriques liées

Company
The name of the company.
Société logistique
The logistic company that contains data that the Infor LN user will work with. This field will only be visible if the parameter for dynamic Logistique - Changement de sté financière (ttaad0101s000) has been enabled.

Rubriques liées

Société financière
The financial company that contains data that the Infor LN user will work with. This field will only be visible if the parameter for dynamic Logistique - Changement de sté financière (ttaad0101s000) has been enabled.

Rubriques liées

Role
The user's default role. If this field is blank, the role mechanism is not available.

A role contains personalization settings, such as session personalizations and menu personalizations.

A role-enabled user has one current role and can have multiple roles assigned. If multiple roles are assigned to a user, the user can switch between these roles.

Langue
The code of the Software Language in which the user starts up the application.
Langue de données
The code of the Data Language of the user.
Explorateur ERP
If this check box is selected, the Explorateur ERP is included in the user's WorkTop at startup.
Explorateur de traitements Infor LN (DEM)
If this check box is selected, the Explorateur de traitements Infor LN (DEM) is included in the user's WorkTop at startup.
Infor LN Workflow
If this check box is selected, the Infor LN Workflow is included in the user's WorkTop at startup.
Menu de démarrage
The package code of the user's startup menu.
Startup Menu
The module code of the user's startup menu.
Startup Menu
The code of the user's startup menu.
Ne pas oublier les paramètres utilisateur 's
If this check box is selected, if the user restarts an overview session, the session starts with the last index the user selected for the session.

If this check box is cleared,

  • Sessions start with the default window size, and the default screen position.
  • Overview sessions start with the default column widths.
  • Overview sessions start with the session's default index.
Remarque

The user can only select a session's index if the Sort by command on the View menu is enabled.

Mode du message
The user's Message mode. At runtime, users can change the message mode in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.
Barre d'outils standard
The location of the user's standard toolbar on a session's form. Users can maintain this field in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.
Barre d'outils d'application (icônes)
The location of the user's application toolbar (icon buttons) on a session's form. Users can maintain this field in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.
Barre d'outils d'application (texte)
The location of the user's application toolbar (text buttons) on a session's form. Users can maintain this field in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.
Données utilisateur
The Tools user's user data template.
Remarque

You create the templates in the Modèle de données utilisateur (ttams1110m000) session.

Groupes de textes par défaut
The Tools user's default text group template.
Remarque

You create the template in the Modèle de groupe de textes par défaut (ttams1121m000) session.

Champs texte par défaut
The Infor LN user's default text field template.
Remarque

You create the template in the Groupe de textes par défaut par modèle de champ de texte (ttams1120m000) session.

Paramètres de développement
The Tools user's development parameters template.

You create the template in the Modèle de paramètres de développement (ttams1150m000) session.

Préférences du périphérique
The Tools user's device preference template.
Rôle
A role of the Infor LN user in an organization.
Remarque

You can link the Tools user to more than one role.

Exemple

A manager must have the same authorizations as his staff in the organization, in addition to his own authorizations.

Role
The description of the role.
Autor. par déft pr ttes VRC d'applications
If this check box is selected, the developer has default authorization to change software components in all package VRCs. If a package VRC is specified in the Modèle d'autorisation du développeur (ttams1151m000) session, the developer will no longer be authorized for all package VRCs, but only for the specified VRC.

If this check box is cleared, the developer is only authorized for the package VRC that is specified in the Modèle d'autorisation du développeur (ttams1151m000) session.

Autorisations développeur
The code of the template in which the authorizations for the developer are specified.
Remarque

You create the template in the Modèle d'autorisation du développeur (ttams1151m000) session.

Autorisations groupe de textes
The code of the template in which the text group authorizations for the Infor LN user are specified.

A textgroup authorization template must be specified for a normal user, otherwise the user is unable to read or write text in Tools.

Remarque

You create the template in the Modèle d'autorisation de groupe de textes (ttams1122m000) session.

Type d'e-mail
The address type of the user's e-mail address.
Adresse e-mail
The e-mail address of the recipient. Infor LN checks the validity of the e-mail address based on the e-mail type.
Téléphone
This field is not yet supported by Infor LN.
Fax
This field is not yet supported by Infor LN.
Télex
This field is not yet supported by Infor LN.
Adresse SITA
This field is not yet supported by Infor LN.
Adresse SMS
This field is not yet supported by Infor LN.
Type d'adresse par défaut
The default address type for the user. Infor LN uses the default when an application does not specify how a message should be sent to the user. If you use a default message type, you must also supply an address for that type. You can also leave this field empty, meaning this user has no default message type.