Sesiones (ttadv2100s000)

Use this session to generate and maintain sessions.

Select the Report Generator button to generate a 4GL report when you modify a session's data.

When you insert a new session (before your first save of a record):

  • You can select the Generate Script check box. Tools generates a program script for the session when you save the record.
  • You can specify the session's standard command set in the St. Command Set field.

On your first save of a new session Tools generates the session.

When you maintain an existing session (after your first save of a record:)

  • The Generate Script check box is removed from the form. To create a program script for your session after the first save, you must manually create a program script in the Program Scripts / Libraries (ttadv2530m000) session, and link it to your session by entering the code in the Program Script field.
  • The St. Command Set field is removed from the Sesiones (ttadv2100s000) details session's form. To reselect your session's standard command set, you must use the Sesiones (ttadv2500m000) overview session. Select the session in the grid, click Standard Commands from the Vistas, Referencias o Acciones menu. The Standard Commands (ttadv3110s000) sessions starts, in which you select the St. Command Set option. The Standard Command Sets (ttadv3520m000) session starts, from which you can select a new standard command set for your session.
Nota

You can only change a session's data if you check out the session. You perform the checkout through the Vistas, Referencias o Acciones menu of the Sesiones (ttadv2500m000) overview session.

 

Paquete
The code of the session's package.
VRC
The version code of the session's VRC.

Temas relacionados

VRC
The release code of the session's VRC.

Temas relacionados

VRC
The customer code of the session's VRC.

Temas relacionados

Módulo
The session's module code. Each session belongs to a module within a package.
Sesión
The session's code. The combination of the package code, module code and the session code uniquely identifies the session.
Description
The session's description, displayed in the title bar of the session's window at runtime.
Standard Script
The session's standard script type.
Nota

If you specify a standard script, you cannot specify a program script.

Valores permitidos:

Possible values

Generate Script
If this check box is selected, when you first save a record Tools generates a session and a program script for the session.

If this check box is cleared, when you first save a record Tools generates a session but does not generate a program script for the session.

Nota
  • You can only maintain this field when you select No in the Standard Script field.
  • You define the code of the generated program script in the Program Script field.
  • The contents of the generated script depends on the settings you select in this session. You can view and maintain the generated program script in the Program Scripts / Libraries (ttadv2530m000) session.
  • After the first save of a new record this checkbox is removed from the form. To create a program script after your first save, you must manually create a program script in the Program Scripts / Libraries (ttadv2530m000) session, and link it to your session by entering the code in the Program Script field.
Program Script
The program script's package code.
Program Script
The module code of the session's program script.
Nota

You can only maintain this field when you select No in the Standard Script field.

Program Script
The program script's code. The package code, module code and program script code identifies the program script that belongs to the session.
Nota

You can only maintain this field when you select No in the Standard Script field.

Main Table
The package code of the session's main table.
Main Table
The module code of the session's main table.
Main Table
The table number of the session's main table. The combination of the package code, the module code, and the table number identifies a table.
Start Command Type
The session's Start Command type.

Valores permitidos:

Type of Start Command

Start Command
The command Tools carries out when a user starts the session.
Nota

You can only maintain this field when you select Specific Start Command in the Start Command Type field.

Session Status
The development status of the session.

Valores permitidos:

Status session

Sesión dinámica
If this check box is selected, the session is dynamic. You can only create dynamic sessions.
Integrated
If this check box is selected, the session is an integrated session. You can only create integrated sessions.
Tipo sesión
Specifies the session's type.

Valores permitidos:

Session Type

Tipo ventana
Specifies the session's window type.

Valores permitidos:

Window type

Main Session
If this check box is selected, the session is a main session and can be placed in a browser menu.

If this check box is cleared, the session is a subsession and cannot be placed in a browser menu. Users can only start the session through an overview session, or by a specific form command.

Synchronized Dialog
The code of an overview session's details session. The details session starts when a user double clicks a record in the overview session.
Expired
If this check box is selected, the session is expired and cannot be used in the package VRC or any of the package VRC's derivatives.
Reports in several languages
If this check box is selected, you can print the session's reports in languages other than the run-time language.
Nota
  • Dependent on software delivery (see the Import- / Export functions module). You can only print reports in the languages you select in the Languages to Deliver by Language (ttiex0101m000) session.
  • You can manage multilingual report printing in the session's program script.
User
The user who created the session.
Date
The date the user created the session.
Nota

You can print a range of sessions selected by their creation date.

Documentación técnica
If this check box is selected, a technical documentation description of the session is available.
Release Notes
If this check box is selected, a release note description of the session is available.
Workflow Enabled
You must use this field to specify if the session can run in a Workflow environment. You can select one of the following values from the list. Only three values of the list has a meaning, see the table below:
ValueDescription
Not checkedThe session has not been checked in a Workflow environment
Single / RedoableThe session has been checked in a Workflow environment and executed successfully
Single / Not RedoableNot used
Container / RedoableNot used
Container / Not RedoableNot used
Single / Container / RedoableNot used
Single / Container/ Not RedoableNot used
Not Workflow EnabledThe session has been checked in a Workflow environment but failed

 

Webtop Enabled
You must select this check box, if you can run the session successfully in a Web UI environment.
Horizontal
If this check box is selected, the properties of each record in an overview session display horizontally (in rows) across the grid. Ejemplo:
itemlengthweight
pie30cm1.0kg
pizza50cm1.5kg

 

If this check box is cleared, the properties of each record in an overview session display vertically (in columns) down the grid. Ejemplo:

itempiepizza
length30cm50cm
weight1.0kg1.5kg

 

Occurrences
The number of records Tools displays in the grid when a user starts the Overview session.
Nota
  • If you enter 1 (one) in this field, the number of records displayed in the grid is determined by the session's default window size.
  • If a user has the Recordar la configuración del usuario check box selected in the Datos de usuarios (ttams1100s000) session, the number of records displayed in the grid is dependent on the user's last selected window size for the session.
Dynamic index switching
Select the session's dynamic index switching options. Valores permitidos:

No- When a user chooses a new index, the view fields and session layout does not change.

Reiniciar al diferir campos- When a user chooses a new index that alters the view fields above the the session's grid, the session restarts.

Reiniciar siempre- When a user chooses any new index by which to view the session, the session restarts.

Show name of index
If this check box is selected, for overview sessions with dynamic index switching implemented, the current index displays in the session's title bar.
St. Command Set
Select a standard command set for your session.
Nota

On your first save of a record, Tools generates the session. After your first save of a record:

  • This field is removed from the form.
  • To reselect your session's standard command set, in the the Sesiones (ttadv2500m000) overview session, select your session in the grid, click Standard Commands from the Vistas, Referencias o Acciones menu. The Standard Commands (ttadv3110s000) sessions starts, in which you select the St. Command Set option. The Standard Command Sets (ttadv3520m000) session starts, from which you can select a new standard command set for your session.
Command Type
Select the command type of the session's default button.

Valores permitidos:

Command as Default Button

Default Button
Select a command for the session's default command button. The default command button is the command LN carries out when a user presses the ENTER key whilst using the session. The default command button is always the first button in the list of command buttons included on a session's form.
Nota

If in the Command Type field you selected:

  • Standard Command, in this field you select the session's default button from the Standard Commands (ttadv3110s000) session.
  • Form Command, in this field you select the session's default button from the Form Commands (ttadv3518m000) session.
Label of Object
You can enter a label code in this field. At runtime the label is visible in the pulldown menu of the session if the session belongs to a multi-main table session.
See for an example the following figure:
[...]
Customization prohibited
If you select this check box, the customize form functionality in a details session and the customize visibility, ordering and width of columns functionality in an overview session is disabled if the session is started from Web UI.