User Data (ttams1100s000)

Use this session to specify the system data, defaults settings, authorizations, and templates applicable for the LN user. The data is necessary for the user to start up a Tools application successfully. In this session you can also specify the Tools user's address data. For example, the e-mail address, telephone number, fax number, and so on.

If you have specified the data for the Tools user, click Close to return to the overview session. Use the commands on the appropriate menu to create the user file in Tools.

Note

A textgroup authorization template must be specified for a normal user, otherwise the user is unable to read or write text in Tools.

 

User

A user code to identify the user as an LN user.

The Tools user code is normally similar to the user code specified in the System Login field. However, you can specify more than one Tools user for one system logon.

When a user starts the bshell, by default the system starts with the Tools user code that is equal to the system logon code. You can start the bshell with a different Tools user code by setting the User environment variable.

Example

System logonLN user
davedave
davedave_01
davedave_02
johnjohn
johnjohn_01

 

If the user with the system logon dave starts the bshell, by default he will be user dave in Tools. The user dave can fill the environment variable User with dave_01 or dave_02, to start as another Tools User.

If the user with the system logon dave sets the environment variable USER to john or john_01 and tries to start the bshell, the message Not authorized to run as user john appears. In the same way, UNIX user john can only start the bshell as Tools User john or john_01, but not as dave, dave_01 or dave_02.

Note

After running the Change length of OS User Names (ttaad2220m000) session, a one-to-one relationship exists between system login and LN User. You can link each system login to only one LN user.

Name

The name of the Tools user.

Infor SSO User

This field is displayed only if the SSO Active check box in the SSO Parameters (ttams0100m000) session is selected. Specify the name of the user as it is known in SSO Service.

You can leave the SSO User field empty. In that case the value of the System Login field is used during the Convert to Runtime. The Infor SSO User must be unique; for example, an Infor SSO User can only be specified for one LN user.

During the convert to runtime this field is dumped into the u<user> file with the sso_user tag.

Also a $BSE/lib/user/sso/s<SSO_USER> file, that contains the Application User name, is created. The format is baanuser:<baan user name>. This file is used by the Bshell to make the mapping from SSO user to Application User.

To prevent that an end user can tamper with the configuration to get more credentials, an extra file $BSE/lib/sso.permissions is introduced for BLogin. This file contains the permissions for SSO users to impersonate a certain OS user. The file is to be maintained by the system administrator and must only be writable on OS level by the system administrator. It must be considered as having the same security status as for example the OS password file. If this file does not exist, BLogin refuses to handle SSO requests.

Use Generic System User

If this check box is selected, the default OS-user identity that is used in SSO mode to run the binaries will be displayed. Any user can impersonate the Generic System User. After conversion this data is placed into the sso_config file as generic_user:<Generic User>.

The Use Generic System User field is enabled if the Overrule System User Allowed check box in the SSO Parameters (ttams0100m000) session is selected.

System Login

The System Login code of the user. The user code specified in the User field is used as the default.

Before installing Tools, a number of system logons have to be created by the system manager by using a system administration program.

Tools checks if the logon code specified in this field exists in the password file. If not, a warning appears.

Important!

You can only specify system login codes that are in lower case.

Note that the System Login field will be disabled when the Use Generic System User field is checked. This is the case when SSO is activated. The value of the displayed Generic System User field will than be used during Convert to Runtime.

User Type

The user type for the LN user.

Package Combination

The user's package combination of the Tools software.

Package Combination

The description of the package combination.

Company

The default company that contains data that the LN user will work with.

Access to a company is only possible if the package combination of the Tools user and company are the same.

There are exceptions to this rule. The company's package combination can only differ from the user's package combination under the following restrictions:

  • Both package combinations must include the same library authorizations.
  • The package VRCs in both package combinations can only be different if both package VRCs are derived from each other, or both package VRCs are derived from the same package VRC, and no changes in data definitions or domains have been made in the derived package VRCs.
Note

If the user is a normal user, the company authorization for the specified company is automatically generated.

Related topics

Company

The name of the company.

Logistical Company

The logistic company that contains data that the LN user will work with. This field will only be visible if the parameter for dynamic Logistic - Financial Company switching (ttaad0101s000) has been enabled.

Related topics

Financial Company

The financial company that contains data that the LN user will work with. This field will only be visible if the parameter for dynamic Logistic - Financial Company switching (ttaad0101s000) has been enabled.

Related topics

Role

The user's default role. If this field is blank, the role mechanism is not available.

A role contains personalization settings, such as session personalizations and menu personalizations.

A role-enabled user has one current role and can have multiple roles assigned. If multiple roles are assigned to a user, the user can switch between these roles.

Language

The code of the Software Language in which the user starts up the application.

Data Language

The code of the Data Language of the user.

Menu browser

If this check box is selected, the Menu browser is included in the user's WorkTop at startup.

Infor LN Process Browser (DEM)

If this check box is selected, the Infor LN Process Browser (DEM) is included in the user's WorkTop at startup.

Infor LN Workflow

If this check box is selected, the Infor LN Workflow is included in the user's WorkTop at startup.

Startup Menu

The package code of the user's startup menu.

Startup Menu

The module code of the user's startup menu.

Startup Menu

The code of the user's startup menu.

Remember the user's settings

If this check box is selected, if the user restarts an overview session, the session starts with the last index the user selected for the session.

If this check box is cleared,

  • Sessions start with the default window size, and the default screen position.
  • Overview sessions start with the default column widths.
  • Overview sessions start with the session's default index.
Note

The user can only select a session's index if the Sort by command on the View menu is enabled.

Message Mode

The user's Message mode. At runtime, users can change the message mode in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.

Standard Toolbar

The location of the user's standard toolbar on a session's form. Users can maintain this field in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.

Application Toolbar (Icons)

The location of the user's application toolbar (icon buttons) on a session's form. Users can maintain this field in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.

Application Toolbar (Text)

The location of the user's application toolbar (text buttons) on a session's form. Users can maintain this field in the Options (ttams1100s100) session, which they can access by clicking Options... on the Tools menu of any overview session.

User Data

The Tools user's user data template.

Note

You create the templates in the User Data Template (ttams1110m000) session.

Default Text Groups

The Tools user's default text group template.

Note

You create the template in the Default Text Groups Template (ttams1121m000) session.

Default Text Fields

The LN user's default text field template.

Note

You create the template in the Default Text Groups by Text Field Template (ttams1120m000) session.

Development Parameters

The Tools user's development parameters template.

You create the template in the Development Parameters Template (ttams1150m000) session.

Device Preferences

The Tools user's device preference template.

Role

A role of the LN user in an organization.

Note

You can link the Tools user to more than one role.

Example

A manager must have the same authorizations as his staff in the organization, in addition to his own authorizations.

Role

The description of the role.

Default Authorization for all Package VRCs

If this check box is selected, the developer has default authorization to change software components in all package VRCs. If a package VRC is specified in the Developer Authorization Template (ttams1151m000) session, the developer will no longer be authorized for all package VRCs, but only for the specified VRC.

If this check box is cleared, the developer is only authorized for the package VRC that is specified in the Developer Authorization Template (ttams1151m000) session.

Developer Authorizations

The code of the template in which the authorizations for the developer are specified.

Note

You create the template in the Developer Authorization Template (ttams1151m000) session.

Text Group Authorizations

The code of the template in which the text group authorizations for the LN user are specified.

A textgroup authorization template must be specified for a normal user, otherwise the user is unable to read or write text in Tools.

Note

You create the template in the Text Group Authorization Template (ttams1122m000) session.

Email Type

The address type of the user's e-mail address.

Email Address

The e-mail address of the recipient. LN checks the validity of the e-mail address based on the e-mail type.

Telephone Number

This field is not yet supported by LN.

Fax Number

This field is not yet supported by LN.

Telex Number

This field is not yet supported by LN.

SITA Address

This field is not yet supported by LN.

SMS Address

This field is not yet supported by LN.

Default Address Type

The default address type for the user. LN uses the default when an application does not specify how a message should be sent to the user. If you use a default message type, you must also supply an address for that type. You can also leave this field empty, meaning this user has no default message type.