Inspection Order - Lines (qmptc0151m000)

Use this session to display or maintain order-specific inspection data lines. For each characteristic or aspect/characteristic combination, an inspection line is available. The data related to this characteristic can be changed for this specific order.

 

Sequence

The sequence number of the order. For each sequence, one or more samples are drawn to test the characteristics.

Line

The number that identifies the inspection order line.

Aspect
Characteristic
Characteristic Type

The type of value that is measured.

Characteristic Unit

characteristic unit

Note

If you selected Fraction or Integer in the Characteristic Type field, you must fill in the Characteristic Unit field. If you selected Option, the Characteristic Unit field will become blank.

Characteristic for Algorithm

If this check box is selected, this characteristic is used as a variable or constant in the algorithm of another characteristic.

Option Set

A group of possible values of a characteristic. For each value (option) you can indicate whether it is acceptable or not.

The options blue and red form an option set

Example
CharacteristicpH value
TestLitmus test
Optionsblue = acceptable
red = not acceptable

 

Note

You can enter an option set if the Characteristic Type field is on Option.

Method

The type of characteristic value or the way in which the characteristic value is calculated.

Algorithm

algorithm

Note

You can only enter data in the Algorithm field, if you entered Algorithm in the Method field. Enter the name of the algorithm that is used to calculate the characteristic.

Test

An examination or check done on a characteristic. You can link one or more tests to a characteristic.

Test Area
Destructive Test

If this check box is selected, the test is destructive and the item cannot be used after testing.

If this check box is cleared, the test is not destructive and the item can be used after testing.

Result Type

The type of result reported to the user.

Test Unit

test unit

Note

The characteristic unit is the default value. The test unit and the characteristic unit must have the same physical quantity.

Test Sequence

The test sequence specifies the sequence in which the characteristics in a test group are tested. If the value of the Test Sequence field is zero, the sequence of this aspect/characteristic is not important for testing. An aspect/characteristic with a zero test sequence value will be tested after all other tests have taken place.

Example

Destructive Test Test Sequence
Test 1No1
Test 2Yes2

 

Explanation: The destructive test will take place last.

Note

The sequence number can be the same for more than one characteristic. When this is the case, the tests will be sorted by aspect/characteristic, unless the test sequence number is zero.

Test Standard

The standard normally used for the test.

For example, a DIN standard

Skill
Employee

The person that performs the test on this characteristic.

Instrument

A tool that is used during quality tests to measure particular characteristics of an item.

Example
Instrumentacidimeter
CharacteristicpH value

 

Instrument Group

The code of the instrument group. The group of instruments with similar characteristics.

Description

The description or name of the code.

Instrument Number

The number of the instrument that can be used to trace the instrument.

Description

The description or name of the code.

Fixed Characteristic Value

A characteristic value that is determined once, and which is compared to the test results entered in the Sample - Test Data by Characteristic (qmptc1115m000) session.

Note

This field only applies if the Method field is set to Fixed.

Characteristic Standard

The standard normally used for characteristics. This is an informative field.

For example, a DIN standard

Value Type

The value type of the characteristic.

Allowed values

Value Type

Chart Name

The code of the chart name to which the nominal values are applicable.

Note

This field is available only if the Nominal option is selected in the Value Type field.

Chart Type

The code of the chart type for which the nominal values are applicable.

Note

This field is available only if the Nominal option is selected in the Value Type field.

Tolerance Standard

The code of the tolerance standard linked to the nominal value range.

Note

This field is available only if the Nominal option is selected in the Value Type field.

Nominal Value

The nominal value of the characteristic, expressed in the characteristic unit.

Note

This field is available only if the Nominal option is selected in the Value Type field.

Norm

The norm is the desired quality for this characteristic, expressed in the characteristic unit.

Note

This field does not apply if you enter Fixed in the Method field or Option in the Characteristic Type field.

Upper Limit

The highest characteristic value, expressed in the characteristic unit for which the quality is acceptable.

Note

The Upper Limit field must be greater than or equal to the value in the Norm field.

Lower Limit

The lowest characteristic value, expressed in the characteristic unit for which the quality is acceptable.

Note

The Lower Limit field must be less than or equal to the value in the Norm field.

Origin

An integrated module or package to which an (inspection) order is related.

Position

The number of the order line to which the inspection order applies. This can be the position of the sales order line, the position of the purchase order line, or the position of the estimated materials.

Operation

One of a series of steps in a routing that are carried out successively to produce an item.

The following data is collected during a routing operation:

  • The task. For example, sawing.
  • The machine used to carry out the task (optional). For example, sawing machine.
  • The place where the task is carried out (work center). For example, woodwork.
  • The number of employees required to carry out the task.

This data is used to compute order lead times, to plan production orders and to calculate cost prices.

A quality inspection must take place, during or after this operation.

 

Validate Algorithm

Checks the validity of the order specific algorithm data.