Infor Cloverleaf Connection
Infor Process Automation provides an activity node that allows one-way communication with an Infor Cloverleaf system. This topic describes how to configure a connection to Infor Cloverleaf which allows a process to send a message to an Infor Cloverleaf-compatible system.
          Note: 
          
         Infor Cloverleaf is a messaging system that is primarily used among health care institutions.
| Property | Description | 
|---|---|
| Configuration The name of the configuration that this connection is associated with. | Select an existing configuration that this connection is associated with. This is a configuration that contains a connection to Infor Cloverleaf. | 
| Connection | If you are not using a configuration for this connection, select an existing connection or configure a new one. | 
| Message Encoding | 
              Choices are: 
  | 
           
| Use Byte Order Mark | Enable this byte order mark to send a byte order mark at the beginning of the data flag that tells which byte is most significant. | 
| Protocol | TCPIP is currently the only available protocol. | 
| Protocol Information | |
| Host | IP address | 
| Port | Infor Cloverleaf port number | 
| Socket Timeout (milliseconds) | Amount of time in milliseconds that the system waits for a return (ack) message before issuing a timeout. | 
| Message Length Indicator | |
| Length of Indicator Field | Sends the length of the indicator field | 
| Fill Character | The fill character for the length of indicator field. | 
| Justification | Indicates whether the value in the length indicator field is right- or left-justified. | 
| Length Calculator | Indicates whether the value in the length indicator field (that is, the field specifying the message length), includes the size indicator field. |