Creating notification parameters

The ION Notification node supports sending parameters to the ION. The ION Notification Parameters Builder walks you through the process of building or modifying notification parameters.

  1. From the ION Notification section, click Build.
  2. Specify values for mandatory keys. To specify the DataType for the parameter, select from the drop-down list (in the Value column).

    All the keys for the parameter element are pre-populated and cannot be edited. Values for mandatory keys are pre-populated with dummy values and can be modified.

  3. Add parameters as needed.

    Use these buttons to construct a parameter:

    Button Description
    Parameter

    Adds a parameter with pre-populated keys and dummy values

    • Name: the name that you want to assign to the parameter

    • Value: the value that you want to assign to the parameter

    • DataType: select from the drop-down list. The options are: String, Integer, Decimal, Boolean, DateTime, Date, and Time.

    • Label: the label that you want to assign to the parameter. In Infor OS Portal, this will appear as the name of the parameter when viewing the details of the notification.

    Delete Deletes one or more selected parameters
    Move Up/Move Down Moves a selected parameter up or down
    Expand All/Collapse All Expands or collapses all the parameters in the builder

    The corresponding XML for the notification detail (as seen in the Notification Detail String box) will be created in the builder dynamically based on the input.