Infor Cloverleaf Connection
Infor Process Automation provides an activity node that allows one-way communication with an Infor Cloverleaf system. This topic describes how to configure a connection to Infor Cloverleaf which allows a process to send a message to an Infor Cloverleaf-compatible system.
Note:
Infor Cloverleaf is a messaging system that is primarily used among health care institutions.
Property | Description |
---|---|
Configuration The name of the configuration that this connection is associated with. | Select an existing configuration that this connection is associated with. This is a configuration that contains a connection to Infor Cloverleaf. |
Connection | If you are not using a configuration for this connection, select an existing connection or configure a new one. |
Message Encoding |
Choices are:
|
Use Byte Order Mark | Enable this byte order mark to send a byte order mark at the beginning of the data flag that tells which byte is most significant. |
Protocol | TCPIP is currently the only available protocol. |
Protocol Information | |
Host | IP address |
Port | Infor Cloverleaf port number |
Socket Timeout (milliseconds) | Amount of time in milliseconds that the system waits for a return (ack) message before issuing a timeout. |
Message Length Indicator | |
Length of Indicator Field | Sends the length of the indicator field |
Fill Character | The fill character for the length of indicator field. |
Justification | Indicates whether the value in the length indicator field is right- or left-justified. |
Length Calculator | Indicates whether the value in the length indicator field (that is, the field specifying the message length), includes the size indicator field. |