Configuring an ION receiver
When you configure an ION receiver, you are telling Infor Process Automation how to handle data that comes in from a particular ION channel.
-
Access the Process Server Administrator and select Administration > Channels Administrator.
-
Select the channel that you would like a receiver to be created.
-
Go to the Inbox Receivers tab.
-
Click Actions > Create.
-
Specify this information:
- Channel Name
-
This field is pre-populated based on the channel for which you are configuring a receiver.
- ION Receiver Type
-
Options are:
-
BOD Group: This receiver listens for BOD types that are part of the specified BOD group.
-
ION Pulse: This receiver listens for ION Pulse BODs.
-
BOD Type: The receiver listens for a specific type of BOD.
The subsections that follow this table provide descriptions of the options for each receiver type.
-
- To Logical ID
-
The ION Connect Logical ID of this Connection Point.
- Description
-
Short description of the receiver
- Scan Frequency (Minutes)
-
Configures how often to scan the Inbox for BODs to process. If the "Run from time" and "Run to time" are configured, the scan will happen only during the indicated time interval.
- Run From Time and Run To Time
-
If you want the scan to look for this BOD during a specific timeframe, for example, 2:00 AM to 4:00 AM, use these fields to configure the start and stop times.
A blank "Run from time" and/or "Run to time" means midnight.
- Startup Type
-
Determines when the receiver starts up. Options are:
-
Automatic: File starts up automatically when the system starts.
-
Manual: File does not start automatically when the system starts. The administrator must start it manually.
-
Disable: The receiver has been taken off-line, does not start.
-
Rcvr Type = BOD Type
The BOD Type receiver is used when you are configuring a single BOD.
Option | Description |
---|---|
BOD Type |
The name of the BOD (XML document) to listen for in the format: Noun.Verb Example: |
Process | The name of the process that triggers when the BOD is received. |
Seq Method |
The sequencing method to use. Available selection are:
|
Number of WU Restarts | Number of times to restart a failed workunit. |
WU Restart Wait Time (Minutes) | Number of minutes to wait before restarting a failed workunit. |
Number of Rescans |
Number of rescans for "out-of-sequence" BODs. Defaults to 1 and applies to Seq Method of "Variation Id Sequence". When a BOD is received "out-of-sequence" (e.g.: has a sequence number that is higher than expected), this option determines how many times to rescan the Inbox in order to wait for the BOD with the expected Variation Id sequence. When the configured rescans are exhausted, it is assumed that the expected BOD sequence was lost or not sent. The receiver will then continue processing the next sequence for the BOD. |
Skip Old BOD Versions | When this flag is enabled and the scan retrieves multiple BODs for the same object, only the latest BOD for the object is processed; the older BODs for the object are skipped. |
Enforce Sequential Batch Id |
Enable if you are receiving BODs in a batch and want the BODs to be processed sequentially by Batch Id. If this option is set to True, the following processing occurs:
If this option is set to False, the following processing occurs:
|
Rcvr Type = BOD Group
BOD Group: The name of the BOD Group
Rcvr Type = ION Pulse
Pulse Type: Select the ION Pulse BOD to process:
-
Pulse Task
-
Pulse Alert
-
Pulse Notification