The tables show the hardware specifications for the recommended configuration:

Infor Ming.le / Infor LN UI Plugin for 1 to 25 and 25 to 50 concurrent users

Requirement Recommended value
Type Infor Ming.le /web server
Server specification Intel Xeon E5 series
CPU 4 cores
Memory 8 GB
Disk space 80 GB/200 IOPs

1 to 25 concurrent users

Requirement Recommended value
Type Infor LN application and database server
Server specification Intel Xeon E5 Series
CPU 1 quad-core Intel Xeon E5-2603, 1800 MHz
Memory 10 GB
Disk space

140 GB of estimated usage per year. The configured space will be higher. This storage space can also be configured on a SAN.

You must use at least six disks for the database component:

  • Operating System (2 disk) RAID 1 is recommended.

  • Database software and database log and archive files (2 disk) RAID 1.

    • Database data files (4 disks) RAID 5 minimum. RAID 10 is recommended for the highest performance and high availability.

    • Swap space must be spread across disks as recommended by the hardware manufacturer.

If SAN storage is used, an I/O capacity of at least 600 IOPS is required.

Disk controller If separate disks are used, for example, SCSII or SAS, we recommend that you use a controller with sufficient write-through cache, of at least 256 MB.

25 to 50 concurrent users

Requirement Recommended value
Type Infor LN application and database server
Server specification 4-Core Intel Xeon E5-2620 Series
CPU 1 Intel Xeon E5-2620, 2000 MHz
Memory 16 GB
Disk space

200 GB of estimated usage per year. The configured space will be higher. This storage space can also be configured on a SAN.

You must use at least six disks for the database component:

  • Operating System (2 disks) RAID 1 is recommended.

  • Database software and database log and archive files (2 disks) RAID 1.

    • Database data files (4 disks) RAID 5 minimum. RAID 10 is recommended for the highest performance and high availability.

    • Swap space must be spread across disks as recommended by the hardware manufacturer.

If SAN storage is used, an I/O capacity of at least 600 IOPS is required.

Disk controller If separate disks are used, for example, SCSII or SAS, we recommend that you use a controller with sufficient write-through cache, of at least 256 MB.