Recording Test Results

Use the QCS Test Record form to generate quality tests and to record test results.

To record the test results:

  1. Select Modules > Infor CloudSuite Industrial Shop Floor > Miscellaneous > QCS Test Record.The QCS Test Record form is displayed.
  2. Specify this information:
    Rcvr
    Specify a receiver. You can use a customer, supplier, or WIP tag as a receiver.
    Ord Type
    Select an order type.
    Lot Size
    Specify a lot size.
    Sample Size
    Specify a sample size.
    Inspector
    Specify an inspector.
    QC Lot
    Specify a QC lot, if applicable.
  3. Click Batch Test to record results for all the tests.
  4. Select a test from the list on the Batch tab and click Select, if Batch Test is selected. Specify this information for the test:
    Minimum
    Specify the minimum test result value.
    Maximum
    Specify the maximum test result value.
    Nominal
    Specify the nominal test result value.
    Qty Tested
    Specify the quantity that was tested.
    Qty Failed
    Specify the quantity that failed.
    Gage
    Select a gage.
    Pass
    Select this check box if the test is passed.
    Gage Expire
    Select this check box if the gage is expired.
    Completed
    Select this check box if the test is completed.
  5. Click Each Test to record results for each test individually..
  6. Select a test from the list on the Each tab and click Select, if Each Test is selected. Specify this information for the test:
    Actual Value
    Specify the test value.
    Actual Gage
    Specify the gage value.
    Pass
    Select this check box if the test was passed.
    Piece Complete
    Select this check box if testing is completed for this piece.
  7. Click the green process button to record the test results.