Recording Test Results
Use the QCS Test Record form to generate quality tests and to record test results.
To record the test results:
- Select Modules > Infor CloudSuite Industrial Shop Floor > Miscellaneous > QCS Test Record.The QCS Test Record form is displayed.
-
Specify this information:
- Rcvr
- Specify a receiver. You can use a customer, supplier, or WIP tag as a receiver.
- Ord Type
- Select an order type.
- Lot Size
- Specify a lot size.
- Sample Size
- Specify a sample size.
- Inspector
- Specify an inspector.
- QC Lot
- Specify a QC lot, if applicable.
- Click Batch Test to record results for all the tests.
-
Select a test from the list on the Batch tab and click Select, if Batch Test is selected. Specify this
information for the test:
- Minimum
- Specify the minimum test result value.
- Maximum
- Specify the maximum test result value.
- Nominal
- Specify the nominal test result value.
- Qty Tested
- Specify the quantity that was tested.
- Qty Failed
- Specify the quantity that failed.
- Gage
- Select a gage.
- Pass
- Select this check box if the test is passed.
- Gage Expire
- Select this check box if the gage is expired.
- Completed
- Select this check box if the test is completed.
- Click Each Test to record results for each test individually..
-
Select a test from the list on the Each tab and click Select, if Each Test is selected. Specify this
information for the test:
- Actual Value
- Specify the test value.
- Actual Gage
- Specify the gage value.
- Pass
- Select this check box if the test was passed.
- Piece Complete
- Select this check box if testing is completed for this piece.
- Click the green process button to record the test results.
- Click Close to close the form without recording test results.
Related topics