Configuring Shop Floor Parameters
Use this form to configure parameters that are applicable to all the Infor Factory Track Shop Floor transactions and forms.
To configure Shop Floor Parameters:
- Select Master Explorer > Modules > Configuration > Parameters > Shop Floor Parameters. The Shop Floor Parameters form is displayed.
-
Specify this information:
- Maximum number of Tasks to Display
- The maximum number of allowed tasks provided in the field must be displayed in the Dispatch List, Assignment List and Resource Assignment of the Resource forms.
- Allow Multiple Tasks by Operator
- Select this check box to allow the operator on working for multiple tasks at the same time.
- Allow Multiple Tasks by Machine
- Select this check box to allow the multiple on working for
multiple tasks at the same time. Note: This functionality is not allowed for machines that have machine integration functionality selected. These machines are only permitted to work on one task at a given point of time.
- Gap Interval (in Minutes)
- The gap interval expressed in minutes applied to the process of starting and stopping multiple tasks for the same operator or machine.
- Show Unassigned Tasks
- Select this check box to display only unassigned tasks in addition to any assigned tasks.
- Supervisor Start Page
- The home page for the supervisor is displayed, after successful login. Select the Resource Summary or Assignment List to determine the starting page for a supervisor login.
- Resource Summary
- The Resource Summary page is displayed, after successful login.
- Assignment List
- The Assignment List page is displayed, after successful login.
- Display Welcome Message
- Select this check box to display welcome message to the supervisor.
- Biometric System in Use
- Select this check box to use the biometric functionality by the
user. If this checkbox is selected, these biometric options are
displayed:
- Biometric Instruction: Enter the instructions for the employee to follow if the Biometric System in use is selected. By default, the application displays this instruction message, Please scan your right index finger.
- Biometric Message Validity (in seconds): Select this to display the valid biometric message for the user. By default, the application displays 30 seconds that the application needs to wait for a successful biometric scan.
- LN Multi Site in Use
- Select this check box to specify the default organization if LN Multi-Site
functionality is enabled.Note: This parameter is available only if feature 9230 is enabled.
- Use Direct Entry as Operator Landing Page
- Select this check box to display the Direct
Entry form when logged in as an operator.Note:
- This parameter is available only if feature 9263 is enabled.
- The Direct Entry form is displayed only if the operator has no active task.
- Click Save.