Configuring Work Center Status Parameters
To configure work center status parameters:
- Select Modules > Configuration > Infor CloudSuite Industrial Setup > Work Center Status Parameters.
-
Create a new parameter set for a work center or select an existing
parameter set to modify:
- To create a new parameters set, click New.
- To modify an existing parameter set, select a work center from the grid.
-
Specify or review this information:
- Work Center
- If you are creating a new parameter set, select a work center. You can select any of the work centers available in ERP system. If you are modifying an existing parameter set, the work center name and description are displayed.
- Refresh Interval
- Specify how often the efficiency percentage must be calculated.
- High Efficiency Level
- Specify the minimum efficiency level that must be reached for a work center to be considered as operating at high efficiency.
- Medium Efficiency Level
- Specify the minimum efficiency level that must be reached for a work center to be considered as operating at medium efficiency. Work centers that have efficiency percentages below this value are operating at low efficiency.
- Click Save.