Setting up a new DataView
To set up (create) a new predefined DataView, use the DataViews Setup form.
- Open the DataViews Setup form and execute Filter-In-Place.
- Initiate a new record.
- In the DataView field, specify a name that best describes the data to be presented.
-
Optionally, to prevent modifications to the DataView by users
other than those with Vendor Developer permissions, select the System Record option.
This option allows you to protect the structure of DataViews that you deliver to customers/users. It prevents others from deleting or modifying any content you provide, while also allowing customers to add their own content.
-
Optionally, to designate a report caption/title, in the Caption Override field, specify the caption.
This can be a translatable string or a literal value.
When specified, this string replaces the default system-generated caption on DataView report outputs.
Note: You can also specify a layout-specific caption override, by setting the Caption Override field on the Layouts tab. If both that and this field have caption overrides, the layout-specific override takes precedence. -
Optionally, use the Criteria Form
drop-down list to select a form to use to collect report criteria.
This option is used primarily when the report requires a significant number of option specifications for data to be collected. When that is a low number, you typically prompt for each option individually; but when there is a significant number, it is easier and faster for the user to specify the data to be collected using a report criteria form.
-
Optionally, use the Maximum Header Height field to
change the height of the column headers. Enter an integer that corresponds to
the number of rows to be made available for the column headers. The default
value is 1 and the maximum value is
9.
When specified, the column names are word wrapped to occupy the space in the header; if the column name is longer than the allotted space, an ellipse is shown to indicate that there is hidden information.
- On the General tab, specify the required and optional information for each IDO that is to be included in the DataView queries.
- Optionally, after specifying each IDO, to make additional IDO specifications for the DataView, click IDO Setup and follow the procedure in the topic Setting additional IDO specifications for a DataView.
- Optionally, use the options on the Input Parameters tab to add input values or ranges.
- Optionally, use the options on the User Permissions tab to control who has access to this DataView.
- Optionally, view information about or make copies of layouts on the Layouts tab.
- Optionally, use the Report Options tab fields to select the report orientation, the maximum cap exceeded notification type, and what regions are to be displayed on the report.
- Save your work.
Note: If the intended use for this DataView is to be used for report output, you should
create an associated report criteria form.