AddNotification
You can use this function for Optiva workflows and Copy Methods.
Purpose
When AddNotification
is called from any
action or copy method, an entry is made in the Notification table for the field in the call
to have a notification.
HEADER
. Note that any existing notification will be overwritten by the value
passed in. Allowable values for severity are 0
, 1
, and 2
. Any other value will
throw an Argument Exception.To learn more about message codes, see the Infor CloudSuite PLM for Process Application Configuration Guide.
detailCode
. rowKey
is reserved for future use. Syntax
Public Function AddNotification(messageCode as String, propertyName As String, severity as int, Optional objSymbol As String = “”, Optional objectKey As String = “”, Optional detailCode as String = “”, Optional rowkey As String = “”) as Long
Arguments
Argument | Description |
---|---|
messageCode |
The customer assigned message code. |
propertyName |
Holds the property name or field name |
severity |
An Optiva defined enum of possible severity levels:
|
Optional objSymbol |
The data object type or the current object type if blank. |
Optional objectKey |
The data object key or the current object key if blank. |
detailCode |
The system detail code that is used to return the new row. |
Optional rowKey |
This is reserved for future use. |
Add Test Example
C_INFO01
C_WARN01
C_ERR01
If you add the following code to a workflow action, it will set Notifications on the Description, Class and Approval Code fields. If one or more of those fields doesn’t exist on the particular Symbol you are testing, an error message is displayed.
AddNotification("C_INFO01", "DESCRIPTION", 0)
AddNotification("C_WARN01", "CLASS", 1)
AddNotification("C_ERR01", "APPROVALCODE", 2)
Return 111