Security override
Suppose the person who imports a formula, item, and specification is not the
         owner; and the Group and Role values in the PER detail code
         are below 7 (read, write, copy). Then the import does not
         succeed in creating or updating data. 
For the import of these objects to succeed, this criteria must be true:
-  The import user is the object’s owner AND the owner
		  security is 
		  
7 (read/copy/write)or15 (read/copy/write/delete). -  OR the import user is not the object’s owner. The import
            user belongs to the group that is associated with the formula AND the group security is
               
7or15. -  OR the role that is associated with the object has a
		  security of 
		  
7or15. 
For example, this import fails unless the importer is JSMITH. This is because the group security is 3 (read/copy) and the role security is 0 (no access). 
<FSFORMULAPER> 
   <GROUP_CODE>ADMIN</GROUP_CODE> 
   <OWNER_CODE>JSMITH</OWNER_CODE> 
   <GROUP_SECURITY>3</GROUP_SECURITY> 
   <OWNER_SECURITY>15</OWNER_SECURITY> 
   <ROLE_SECURITY>0</ROLE_SECURITY>
   <FORMULA_ID>2858</FORMULA_ID>
</FSFORMULAPER>
      A master user can disable security settings for the purposes of import.